Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING

Entered Date:

09/21/2021

Applicant:

BIZAK DAVID J & MARY M CP/RS

Description:

HOUSE FIRE

Outstanding Inspections

Case Number: T21DV06657
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV06657
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
09/21/2021 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, MET WITH TFD INVESTIGATORSWHO STATED THEY FELT THE FIRE STARTED ON THE STOVEMOVED UP TO THE CABINETS AND THEN INTO THE REAR WALL. SPOKE WITH S/W GAS WHO STATED LINE TEST CHECKED OUT OK AND THERE WAS NO GAS TO THE UNITS. TEP WAS ON SITE, WAITING FOR THE OWNER TO EXPLAIN WHY THERE WAS A THIRD METER, OWNER STATED THE THIRD METER WAS TO ACTUALLY METER THE AMOUNT OF ELECTRIC WAS BEING USED BECAUSE OWNERS PAY FOR ELECTRIC. TEP WENT AHEAD AND TURNED OFF POWER TO THE UNIT AND REMOVED THE METER. INSIDE THE UNIT I FOUND THERE WALL BEHIND THE STOVE WAS A PLUMBING WALL WITH A SIZABLE VOID BETWEEN WALLS, THIS KEPT THE PLUMBING FROM BEING FIRE DAMAGED AND KEPT ELECTRICAL DAMAGE TO A MINIMUM, ONLY THE BOX AND WIRING TO FOR THE MICOWAVE WERE AFFECTED. KITCHEN CABNETS WERE FIRE DAMAGED AND VERY HEAVY SMOKE DAMAGE THRU OUT THE KITCHEN AREAM SOME PERSONAL ITEMS WERE FIRE DAMAGED AND STOVE WAS FIRE DAMAGED. THERE WAS WATER DAMAGETHRU OUT THE KITCHEN AND LIVING ROOM. THE DBEDROOMS AND BATH BOTH HAD HEAVY SMOKE DAMAGE. OCCUPANT'S DOG DIED IN THE FIRE, SHE HAD LEFT WITH THE DOG TO TAKE DOG TO PACC AND SHE STATED SHE WOULD BE STAYING WITH A FRIEND. OWNER ARRIVED ON SITE, WE WALKED THE UNIT, THERE WERE NO BROKEN WINDOW OR DOOR OPENINGS. OWNER CLOSED DOORS AND PARTIALLY CLOSED THE WINDOWS AS WE WALKED OUT. PROPERTY HAD A WALL COMPLETELY AROUND THE PERIMETER AND A DOUBLE GATE THAT WAS LOCKED AT NIGHT. A EMERGENCY NOTICE OF ABATEMENT/ ORDER TO VACATE WAS ISSUED DUE TO THE CONDITION OF THE UNIT. CELINGS AND WALLS WERE VERY BLACKENED. OWNER WAS NOTIFYED THAT A PERMIT WOULD BE REQUIRED FOR REPAIRS INCLUDING A ELECTRICAL RECONNECT. OWNER ASKED THAT A DO NOT ENTER PLACARD BE POSTED ON THE FRONT WINDOW. ALL ISSUES WERE ADDRESSED. COMPLIANCE / CLOSE CASE.

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T21DV06657
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
09/22/2021 NOTICE OF VIOLATION ISSUED