Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING
Address:

Entered Date:

09/10/2021

Applicant:

DALY JOHN & MARGARET TR ATTN: MARGARET H DALY TR

Description:

HOUSE FIRE EVENT NUMBER 212520358

Outstanding Inspections

Case Number: T21DV06279
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV06279
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
09/10/2021 INSP - INITIAL CODE ENFORCMENT BERMUDEZ Approved ON SITE; WITH TFD CASE NUMBER T2167688 AND TPD CASE NUMBER 2109100013; UPON ARRIVAL FIRE HAS BEEN EXTINGUISHED, NO PERSONS FOUND ON THE PROPERTY, THIS IS A COMMERCIAL LOT WITH STORAGE, CAMPER TRAILERS AND A WORKSHOP BUILDING STRUCTURE. FIRE ORIGINATED IN TWO DIFFERENT PLACES. ONE FIRE WAS IN A WHITE TRAVEL TRAILER LOCATED ON SOUTHEAST CORNER OF LOT, WHICH IS A TOTAL LOSS. THE OTHER FIRE WAS IN THE MAIN BUILDING STRUCTURE LOCATED AT THE SOUTHWEST CORNER OF THE LOT. FIRE DAMAGE THROUGHOUT SOUTHWEST END OF BUILDING STRUCTURE. CHARRED WOOD FRAMING, EXPOSING CHARRED RAFTERS AND SIDING, MISSING SIDING AND ROOF. THE BUILDING STRUCTURE HAS MULTIPLE EXTENTION CORD ABUSE THROUGHOUT, UNAPPROVED WIRING THROUGHOUT STRUCTURE. UNAPPROVED WIRING METHODS FOUND AT ELECTRICAL SUB PANELS AND MAIN DISCONNECT. TEP HAS DISCONNECTED ALL POWER LEADING TO THE PROPERTY. NO GAS SERVICE TO PROPERTY FOUND. EASTSIDE FENCE LINE RUNNING NORTH TO SOUTH HAS EITHER FALLEN OR WAS KNOCKED DOWN BY TFD FOR FIRE ACCESS. FRONT GATE LOCKS AND WESTSIDE FENCE HAS BEEN CUT BY TFD FOR ENTRY ONTO PROPERTY DUE TO MULTIPLE FIRES ON THE PROPERTY. WILL ISSUE NOTICE FOR UNSAFE TO OCCUPY FOR TRAILER AND BUILDING STRUCTURE. WILL ATTEMPT TO CONTACT OWNERS. CE WILL HAVE CITY CONTRACTOR INSTALL TEMPORARY FENCE PANELS AND CITY WILL APPLY LOCKS TO FRONT GATES TO SECURE PROPERTY. WILL REFER TO AREA INSPECTOR.

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T21DV06279
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
09/10/2021 CONTACTED BY MAILING
09/10/2021 NOTICE AND ORDER ISSUED
09/10/2021 VIOLATION CLOSED
09/10/2021 STRUCTURE SECURED BY ???
09/10/2021 CALLBACK

Documents

File Name Document Type  
2021-09-10-00-56-14_AATSC.JPG DOCUMENTS VIEW
2021-09-10-02-51-46_AATSC.JPG DOCUMENTS VIEW
2021-09-10-02-52-01_AATSC.JPG DOCUMENTS VIEW
2021-09-10-02-59-32_AATSC.JPG DOCUMENTS VIEW
CAMSCANNER 09-10-2021 15.35.PDF DOCUMENTS VIEW
2021-09-10-00-54-18_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-54-47_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-54-54_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-55-19_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-55-34_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-51-41_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-52-15_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-52-37_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-52-52_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-53-43_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-50-12_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-50-21_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-50-35_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-50-47_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-51-11_AATSC.JPG DOCUMENTS VIEW
2021-09-10-00-45-41_AATSC.JPG DOCUMENTS VIEW