Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T21DV05549
Case Details
Status:
Closed - Resolved
Type:
has a hole in hole in bathroom cieling of trailer that continuesly leaks. also has a bug infestation
Address:
Entered Date:
08/19/2021
Applicant:
N/A
Description:
Case Violations
Case Number: T21DV05549
Case Status: Closed - Resolved
Case Description: has a hole in hole in bathroom cieling of trailer that continuesly leaks. also has a bug infestation
Total Violations: 12
Violation Date | Code Statue |
---|---|
08/26/2021 | T.C. Ch. 6, IRC adopted. R311.7.8 HANDRAILS Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. R311.7.8.1 - Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). |
08/26/2021 | T.C. Ch. 6, IRC adopted. R311.7.1 STAIRWAY WIDTH Stairways shall not be less than 36 inches (914 mm) in clear width at all points above the permitted handrail height and below the required headroom height. Handrails shall not project more than 4.5 inches (114 mm) on either side of the stairway and the minimum clear width of the stairway at and below the handrail height, including treads and landings, shall not be less than 31.5 inches (787mm) where a handrail is installed on one side and 27 inches (698 mm) where handrails are provided on both sides. |
08/26/2021 | T.C. Ch. 16, Sec. 16-11(f)(5) INTERIOR SURFACES AND FEATURES All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
08/26/2021 | T.C. Ch. 16, Sec. 16-11(c)(1) ELECTRICAL SYSTEM All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. |
08/26/2021 | T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons. |
08/26/2021 | T.C. Ch. 16, Sec. 16-13(a) ACCUMULATION OF VEGETATION PROHIBITED Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of the accumulation or untended growth of vegetation. The accumulation or untended growth of vegetation means the presence of plants on property that create a fire, safety or health hazard, or that attract vermin either on the property, on neighboring properties, or on both, and includes but is not limited to: (1) Any lawn grass that exceeds 6 inches in height; (2) All weeds that exceed 6 inches in height; (3) Dead trees and dead shrubs; (4) Dead palm fronds within ten feet of the ground, a structure, a fence or wall, or of any combustible other than the tree from which the fronds have grown; (5) Any tree, shrub, or other form of vegetation of any kind on the property or on the adjoining right-of-way, street, or alley that extends over or under the sidewalk space or roadway in a manner that may interfere with the reasonable use of the street, sidewalk, or alley for pedestrian or vehicular traffic of any kind or that may obstruct the view or light distribution of traffic-control devices or luminaries. Vegetation must be trimmed and maintained to provide an unobstructed pedestrian path a minimum 48 inches in width and 80 inches in height from grade. |
08/26/2021 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
08/26/2021 | T.C. Ch. 16, Sec. 16-11(b)(3)(b) VENTILATION Bathrooms, laundry rooms, water closet compartments and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than 1 ½ square feet. A mechanical ventilation system connected directly to the outside may be provided in lieu of these required exterior openings for natural ventilation in bathrooms that contain a bathtub, shower or combination thereof; laundry rooms; and similar rooms. Such a system must be capable of providing 5 air changes at the rate of 50 cubic feet per minute if the system operation is intermittent; or 20 cubic feet per minute if the operation is constant. The point of discharge of exhaust air shall be at least 3 feet from any opening into the building. In bathrooms containing only a water closet, lavatory or combination thereof; or in similar rooms, ventilation may be provided with an approved mechanical recirculating fan or a similar device designed to remove odors from the room. |
08/26/2021 | T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition. |
08/26/2021 | T.C. Ch. 16, Sec. 16-12(a)(4) WINDOWS, SKYLIGHTS, AND DOORS Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. |
08/26/2021 | T.C. Ch. 16, Sec. 16-4 PERMITS REQUIRED Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
08/26/2021 | T.C. Ch. 16, Sec. 16-11(a)(3) FIRE SAFETY Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
Completed Inspections
Case Status: Closed - Resolved
Case Number: T21DV05549
Case Description: has a hole in hole in bathroom cieling of trailer that continuesly leaks. also has a bug infestation
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/20/2021 | COT - ENFC - Code Enforcement - Initial | Passed | {Activity date: 08/20/2021; Status: Approved; Inspector: VIDAL; Comment: Entered by VIDAL - No one is home and was able to check the traile from the exterior. Has a wood frame roof added to the existing and the roof appears to be leaking. Has a new mini-split system for the AC and heating for the trailer. Has no steps on the rear door at this time. Did call the phone number and left a message. Will do N.O.V. RV.} | |
01/05/2024 | COT - ENFC - Code Enforcement - Follow Up | Passed | All issues have been addressed. Violation Abated, Close Case. RV. |
Completed Case Activity
Case Number - T21DV05549
Case Status: Closed - Resolved
Case Description: has a hole in hole in bathroom cieling of trailer that continuesly leaks. also has a bug infestation
Description | Date | Status |
CONTACTED BY MAILING | 08/26/2021 | Passed |
NOTICE OF VIOLATION ISSUED | 08/26/2021 | Passed |