Case: T21DV04142
Case Details
Entered Date:
06/30/2021
Applicant:
2152 COUNTRY CLUB LLC
Description:
WORK WITH OUT PERMITS
Outstanding Inspections
Case Number: T21DV04142
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T21DV04142
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/30/2021 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved |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|
09/22/2021 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ADVISED ARCHITECT THAT THE MULTIPLE PLANS SUBMITTED ON THE 15TH OF SEPT DID NOT INCLUDE UNIT 19 |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T21DV04142
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 9
Date | Name |
07/01/2021 | CONTACTED BY PHONE |
07/01/2021 | CONTACTED IN PERSON |
07/01/2021 | CONTACTED BY MAILING |
07/01/2021 | CONTACTED BY EMAIL |
07/01/2021 | NOTICE AND ORDER ISSUED |
07/01/2021 | STOP WORK ORDER ISSUED |
07/02/2021 | CITATION ISSUED |
07/01/2021 | VIOLATION CLOSED |
07/01/2021 | 8-5 CITY COMM EMERGENCY |