Case: T21DV03304
Case Details
Entered Date:
06/02/2021
Applicant:
ANDREW J & BRIANA E GRYZYNGER JT/RS
Description:
LEAKS IN THE CIELING. WIRING IS GIVING ELECTICAL ISSUES . HVAC ISSUES DUCT SYSTEM U=IS NOT VENTING OUTSIDE . RAT INFESTATION
Case Violations
Case Number: T21DV03304
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
Violation Date | Code Statue |
---|---|
06/09/2021 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
06/09/2021 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
06/09/2021 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
06/09/2021 | T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons. |
06/09/2021 | T.C. Ch. 16, Sec. 16-12(b)(2) WALLS. Exterior walls shall be maintained in a sound condition that is substantially weathertight and weatherproof, and shall be protected from the elements by paint or other approved protective covering. Exterior walls must be free of loose, crumbling or deteriorated plaster or rotted, split or buckled exterior wall coverings. |
07/14/2022 | VIOLATION CLOSED |
Completed Inspections
Case Status: COMPLIAN
Case Number: T21DV03304
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/09/2021 | INSP - INITIAL CODE ENFORCMENT | MENDOZA | Approved | ON SITE INSPECTION: Open ground in Den east of kitchen. One outlet inoperable. Electrical box for cable is not properly secured to the wall. Front living room window shows signs of leaks, window sill is deteriorated and damaged. Electrical box for cable is not secured Guest bedroom shows signs of water leaks in the window and closet frame Main child room wall shows signs of water damage possibly from abutting laundry room. Laundry room - wall damage around water heater area from possible past water leak. Area abutts bedroom with same damage. Wall outlet on the east wall tests open ground. Ceiling shows signs of water damage around light fixtures Unkown/exposed vent duct in the furnace room. Rodent droppings in the furnace closet. Attic. Unsecured Romex throughout. Improper recessed light instal, wiring touching metal at connection boxes. Lights flicker when unsecured junction box is moved. Vent pipe for fire pit not attached and venting into the attic. Fire pit Ducts in attic not secured. Signs of exterior wall burning around fire pit. Aerials show installed between 2002/2005 withou permit. Wall damage in the attic on the north wall exposed to the exterior, near the attic vent. Rodent droppings throughout the attic Unknown exposed and improperly connected romex on the east side of the home exterior along the ground. Unsecure wiring next to sub panel on the east side wall. Exterior outlet on the east wall is inoperable and does not have proper access due to damage/inproper bubble cover. Exterior outlet near front door test as open neutral |
07/14/2022 | INSP - FOLLOW UP CODE ENFORCE | MENDOZA | Approved | ALL REPAIRS COMPLETED BY CONTRACTOR |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T21DV03304
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date | Name |
06/07/2021 | CONTACTED BY PHONE |
06/09/2021 | CONTACTED BY MAILING |
06/09/2021 | CONTACTED BY EMAIL |
06/09/2021 | NOTICE OF VIOLATION ISSUED |
06/09/2021 | REFERENCE |