Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

01/25/2021

Applicant:

BARNETT LUIS OROZCO & CARRILLO DE OROZCO MARIA L & CORELLA LUIS ROBLEDO JT/RS

Description:

house fire Event# F210250137

Outstanding Inspections

Case Number: T21DV00377
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV00377
Case Description: EMERGENCY
Total Completed Inspections - 1
End Date Description Inspector Results Comments
01/25/2021 INSP - INITIAL CODE ENFORCMENT BERMUDEZ Approved ADDRESS: 812 W BAFFIN DR OWNER/ OCCUPANT: BARNETT LUIS OROZCO & CARRILLO DE OROZCO MARIA L & CORELLA LUIS ROBLEDO CAUSE OF DAMAGE: HOUSE FIRE LOCATION OF DAMAGE: ATTATCHED WASH ROOM BUILDING: THERE IS FIRE DAMAGE TO THE ENTIRE NORTH SIDE EXTERIOR AND INTERIOR ATTATCHED WOOD FRAME WASH ROOM STRUCTURE. CHARRED RAFTERS, INTERIOR AND EXTERIOR WOOD PANELING, ROOF, AND DOOR OF WASH ROOM. KITCHEN WINDOW NORTH OF DWELLING SUSTAINED FIRE DAMAGE AND IS BROKEN AND MISSING. THERE IS FIRE DAMAGE TO EXTERIOR WALLS OF BUIDING IN THE IMMEDIATE AREA OF THE FIRE. HEAVY SMOKE DAMAGE TO KITCHEN WALL COVERINGS. TWO TFD VENT HOLES IN ROOF OF DWELLING. MULTIPLE INSPECTION HOLES IN HALL BATH AND MASTER BATH ROOMS AS WELL AS MASTER CLOSET. MISSING DRYWALL EXPOSING INSULATION AND WOOD FRAMES. ELECTRICAL: THE FIRE DAMAGE ZONE HAS MULTIPLE ELECTRICAL DEVICES IN CLOSE PROXIMITY TO THE FIRE. MELTED ELECTRICAL WIRING EXPOSED. THERE WAS ELECTRICAL DEVICES PLUGGED INTO OUTLETS THAT APPEARED TO BE THE SOURCE OF THE FIRE. THERE IS ALSO EXTENSION CORD ABUSE AND UNAPPROVED WIRING METHODS THROUGH OUT THE HOME. THE SERVICE PANEL HAS EXPOSED WIRING, MISSING BREAKERS, POSSIBLE DOUBLE LUGGING, WIRES MELTED TO REAR OF COVER AND PANEL IS NOT CODE COMPLIANT. CONDUIT EXITING THE SERVICE PANEL, BURNED FROM THE INSIDE OUT. POWER WAS DISCONNECTED BY TEP. PLUMBING: HOT WATER HEATER IN CLOSE PROXIMITY TO THE FIRE DAMAGE ZONE. MECHANICAL: EXPOSED AND DAMAGED DUCT WORK LEADING TO EXHAUST FANS AND VENTS. REMARKS: THIS HOME IS NOW CONDEMNED AND PERMITS ARE REQUIRED FOR REPAIRS. OWNER WILL SECURE THE HOME. GAS SERVICE HAS BEEN TURNED OFF AND TAGGED. WILL REQUIRE PERMITS TO RECONNECT UTILITES.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T21DV00377
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
02/08/2021 CONTACTED BY PHONE
01/25/2021 CONTACTED IN PERSON
01/25/2021 RED CROSS / PRIMAVERA
01/25/2021 NOTICE AND ORDER ISSUED
01/25/2021 VIOLATION CLOSED
01/25/2021 STRUCTURE SECURED BY ???
01/25/2021 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
DAMAGE REPORT 812 W BAFFIN DR RFIRE.DOC DOCUMENTS VIEW
CAMSCANNER 01-25-2021 16.42.PDF DOCUMENTS VIEW
2021-01-25-14-46-15_AATSC.JPG IMAGES VIEW
2021-01-25-14-46-15_AATSC.JPG IMAGES VIEW
2021-01-25-14-46-19_AATSC.JPG IMAGES VIEW
2021-01-25-14-46-40_AATSC.JPG IMAGES VIEW
2021-01-25-14-46-43_AATSC.JPG IMAGES VIEW
2021-01-25-14-45-35_AATSC.JPG IMAGES VIEW
2021-01-25-14-45-35_AATSC.JPG IMAGES VIEW
2021-01-25-14-45-47_AATSC.JPG IMAGES VIEW
2021-01-25-14-45-55_AATSC.JPG IMAGES VIEW
2021-01-25-14-45-57_AATSC.JPG IMAGES VIEW
2021-01-25-14-45-04_AATSC.JPG IMAGES VIEW
2021-01-25-14-45-04_AATSC.JPG IMAGES VIEW
2021-01-25-14-45-07_AATSC.JPG IMAGES VIEW
2021-01-25-14-45-11_AATSC.JPG IMAGES VIEW
2021-01-25-14-45-30_AATSC.JPG IMAGES VIEW
2021-01-25-14-34-44_AATSC.JPG IMAGES VIEW
2021-01-25-14-34-51_AATSC.JPG IMAGES VIEW
2021-01-25-14-35-06_AATSC.JPG IMAGES VIEW
2021-01-25-14-35-33_AATSC.JPG IMAGES VIEW
2021-01-25-14-35-42_AATSC.JPG IMAGES VIEW
2021-01-25-14-34-11_AATSC.JPG IMAGES VIEW
2021-01-25-14-34-40_AATSC.JPG IMAGES VIEW