Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

12/24/2020

Applicant:

EDGAR IVAN GONZALEZ BARRAGAN & ZACIL GONZALEZ CP/RS

Description:

HOUSE FIRE

Outstanding Inspections

Case Number: T20DV08102
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV08102
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/24/2020 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL DOCUMENTS AND PHOTOS IN ONBASE ,, CLOSE CASE
12/24/2020 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD: THERE IS FIRE DAMAGE TO THE CARPORT AND HOME. DAMAGE TO THE CARPORT IS A TOTAL LOSS, ALL WOOD MEMBERS HAVE BEEN DESTROYED. THE CARPORT ESTIMATED DIMENSIONED AT 15 FEET BY 25 FEET. THE HOME CONSTRUCTION IS BLOCK TYPE. THE ADJACENT BLOCK WALL HAS SEVERE CRACKS IN THE MORTAR JOINTS WHICH SPAN 15 FEET IN WIDTH AND 7 FEET IN HEIGHT. THE BLOCKS ABOVE THE SLIDER OPENING HAVE DISLODGED OUTWARD, THE STEEL LINTEL HAS BOWED DUE TO THE HEAT. THE SLIDER DOOR HAS BEEN DESTROYED ALONG WITH THE FRAMING. THE EAVE AREA TO THE FRONT OF THE HOME ALSO SUSTAINED DAMAGE TO AN AREA OF 2 FEET. THE REAR ADDITION EAVE AREA AND THERE TWO ROOF RAFTER WITH SEVERE CRACKS AND DAMAGED ROOF DECKING THE EXIT DOOR SUSTAINED FIRE DAMAGE. THIS EAVE AREA IS ESTIMATED AT 10 FEET. THE ROOF COVERING IS DAMAGED TO AN AREA ESTIMATED AT 15 FEET BY 30 FEET. THERE IS DAMAGE TO THE CEILING SHEET ROCK IN THE DINING ROOM AREA. THERE ARE MORE VISIBLE CRACKS IN THE BLOCK SPANNING THE SAME DISTANCE AS MENTIONED ABOVE. ELECTRICAL: THERE ONE OUTLET OUTSIDE IN THE CARPORT AREA WITH BARE BURNT WIRING, THE INTERIOR FIXTURES AND DEVICES HAVE HEAT DAMAGE, POWER WAS DISCONNECTED BY TEP PLUMBING: GAS WAS SHUT OFF AT THE METER BY SWG MECHANICAL: HEAVY SMOKE TO INTERIOR REMARKS: PERMIT REQUIRED FOR REPAIRS, CITY OF TUCSON SECURED THE DAMAGED OPENINGS AND FENCED THE CARPORT AREA. THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T20DV08102
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
04/02/2021 CONTACTED BY PHONE
12/24/2020 CONTACTED IN PERSON
12/24/2020 NOTICE AND ORDER ISSUED
12/24/2020 VIOLATION CLOSED
06/01/2021 SEC LEIN PLACED ON PROPERTY IN THE AMOUNT OF ???
12/24/2020 STRUCTURE SECURED BY ???
12/24/2020 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
226 W CALLE ANTONIA.PDF DOCUMENTS VIEW
20201224_072741.JPG DOCUMENTS VIEW
20201224_074815.JPG DOCUMENTS VIEW
20201224_074833.JPG DOCUMENTS VIEW
20201224_075109.JPG DOCUMENTS VIEW
20201224_075125.JPG DOCUMENTS VIEW
20201224_090933.JPG DOCUMENTS VIEW
20201224_095521.JPG DOCUMENTS VIEW
20201224_095533.JPG DOCUMENTS VIEW
20201224_100310.JPG DOCUMENTS VIEW
226 E CALLE ANTONIA.PDF DOCUMENTS VIEW