Case: T20DV08074
Case Details
Entered Date:
12/22/2020
Applicant:
N/A
Description:
Completed Inspections
Case Status: Closed - Resolved
Case Number: T20DV08074
Case Description: VACANT AND UNSECURED
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2020 | COT - ENFC - Code Enforcement - Initial | Passed | {Activity date: 12/22/2020; Status: Approved; Inspector: VALDEZ; Comment: Entered by VALDEZ - EMERGENCY CALL OUT BY TPD: UNIT NUMBER 5 HAS A UNFINISHED BASEMENT WHICH WAS PREVIOUS SECURED BY BOARDING WAS BEING USED BY TRANSIENT. THE OPENING WAS BOARDED BY THE CITY OF TUCSON AND POSTED UNFIT TO OCCUPY. UNIT 5 IS A DUPLEX WITH A FIRE DAMAGED UNIT IDENTIFIED AS UNIT 1. THE SERVICE IS COMPRISED OF A GUTTER BOX WITH THREE 60 AMP DISCONNECTS. THERE ARE MULTIPLE CODE VIOLATIONS WITH THE DISCONNECTS UNIT 1 MAIN DISCONNECT HAS POWER OFF AND THE PANEL HAS UNUSED OPENINGS WITH MISSING DEVICES SUCH AS CIRCUIT BREAKERS AND EXPOSED WIRING, THERE ARE MULTIPLE CABLES EXPOSED AND UNPROTECTED. UNIT 5 MAIN DISCONNECT HAS UNUSED OPENINGS AND ELECTRICAL METAL TUBING AND METAL CLAD CABLE CONDUIT WHICH ARE NOT CODE COMPLIANT. UNIT 2 MAIN DISCONNECT HAS UNUSED OPENINGS THE GROUNDING ELECTRODE CONDUCTOR RUNS OVER HEAD TO UNKNOWN DESTINATION, FINAL CONNECT MUST BE VERIFIED. THIS PROPERTY CONSIST OF THE FOLLOWING: ONE DUPLEX IDENTIFIED AS UNITS 1 AND 5, TWO SINGLE FAMILY RESIDENCES IDENTIFIED AS UNITS 2 AND 3 ONE 1800 SQ FOOT GARAGE ONE 2400 SQ FOOT GARAGE WITH CANOPY THIS GARAGE HAS A NEW 125 AMP PANEL WHICH WAS FOUND IN A HAZARDOUS STATE. THE HAZARDOUS CIRCUIT WAS SHUT OFF. THERE IS NO PERMIT FOR THIS INSTALL. THERE IS AN ACCESSORY STRUCTURE DIMENSIONED AT AN ESTIMATE OF 25 X 40, THIS IS A WOOD FRAMED BUILDING CURRENTLY BOARDED AND IN A DILAPIDATED STATED. THE BUILDING SIT ON A STEM WALL TYPE FOUNDATIONS THERE IS FIRE DAMAGE TO THE EXTERIOR SURFACE OF THE BUILDING WEST SIDE, THE BUILDING HAS MULTIPLE TORN PENETRATIONS TO AREAS OF THE WALLS. THIS BUILDING IS VACANT AND NEGLECTED THERE IS NO RECORD FOUND OF THIS BUILDING HAVING LEGAL STATUS ON THIS PROPERTY. THE PIMA COUNTY PROPERTY RECORD CARD DOES NOT DEPICT NOR IDENTIFY THIS BUILDING. } |
Completed Case Activity
Case Number - T20DV08074
Case Status: Closed - Resolved
Case Description: VACANT AND UNSECURED
| Description | Date | Status |
| 8-5 CITY COMM EMERGENCY | 12/22/2020 | Passed |
| STRUCTURE SECURED BY ??? | 12/22/2020 | Passed |
| NOTICE AND ORDER ISSUED | 12/22/2020 | Passed |
| NOTICE OF VIOLATION ISSUED | 12/22/2020 | Passed |
| CONTACTED IN PERSON | 12/22/2020 | Passed |