Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

12/09/2020

Applicant:

JOHANNAH M RIDDLE & GAIL ANN PURDOM

Description:

HOUSE FIRE

Outstanding Inspections

Case Number: T20DV07836
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV07836
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/09/2020 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD: THERE IS FIRE DAMAGE TO THE ROOF MEMBERS OF THE BEDROOM AREA, ESTIMATED AREA IS 8 FEET BY 8 FEET OF DECKING BOARDS, 4 VISIBLE TRUSSES HAVE DEEP CRACKS WITH AREA OF CHARRING. THE CEILING SHEETROCK IS DAMAGED TO THE BEDROOM ROOM DIMENSION ESTIMATE IS 8 X 8. THE ADJACENT ROOM HAS ONE INSPECTION HOLE 1 X 1. FLOORING IN DAMAGED BEDROOM IS WET. TWO ENCASEMENT WINDOWS HAVE BROKEN PANES THE WOOD FRAMED PORCH MEMBERS HAS DAMAGE TO AN AREA OF 8 X 20. 10 2 X6 RAFTER HAVE CRACKING, (1) 4X8 BEAM HAS SURFACE CRACKS. OBS DECKING IN THE AREA ALSO HAS CRACKS. MULTIPLE RAFTER BLOCKING DAMAGED. ALL WOOD MEMBERS ARE DISCOLORED. ELECTRICAL: PORCH AREA HAS BARE AND BURNT WIRING REAR OF RAFTER BLOCKING, THE BEDROOM HAS CEILING FAN DAMAGED, WALL DEVICES / OUTLETS IN CLOSE PROXIMITY TO THE FIRE . TEP DID DISCONNECT POWER. PLUMBING: N/A MECHANICAL: HEAVY SMOKE REMARKS: PERMIT REQUIRED FOR REPAIRS, THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY.
12/16/2020 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL DOCUMENT ARE IN ONBASE CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T20DV07836
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
12/09/2020 CONTACTED IN PERSON
12/09/2020 NOTICE AND ORDER ISSUED
12/09/2020 VIOLATION CLOSED
12/09/2020 STRUCTURE SECURED BY ???
12/09/2020 CALLBACK

Documents

File Name Document Type  
909 NOV.PDF DOCUMENTS VIEW
909 W DREXEL RD.PDF DOCUMENTS VIEW
20201209_005428.JPG DOCUMENTS VIEW
20201209_005432.JPG DOCUMENTS VIEW
20201209_005610.JPG DOCUMENTS VIEW
20201209_010459.JPG DOCUMENTS VIEW
20201209_010512.JPG DOCUMENTS VIEW
20201209_023309.JPG DOCUMENTS VIEW
20201209_023535.JPG DOCUMENTS VIEW