Case: T20DV06492
Case Details
Entered Date:
09/28/2020
Applicant:
IRENE DIAZ RADILLO
Description:
house fire
Outstanding Inspections
Case Number: T20DV06492
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T20DV06492
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2020 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED SITE, MET WITH TFD INVESTIGATORS WHO STATED THEY WERE CALLED TO THE PROPERTY FOR A GARAGE FIRE AND THE FIRE WAS CONTAINED TO THE GARAGE, DID NOT SPREAD INTO THE MAIN HOUSE. UPON MY ARRIVAL I FOUND THE FOLLOWING: >TEP HAD BEEN TO THE PROPERTY, AT THE REQUEST OF TFD HAD TURNED OFF THE POWER AND REMOVED THE METER. >S/W GAS HAD TURNED OFF THE GAS AND PINNED GAS METER. >TPD WAS CALLED OUT TO THE SCENE AFTER FIRE FELT THAT THE FIRE MAY NAVE STARTED OUTSIDE THE BUILDING BELOW A AIR VENT THAT PULLS FRESH AIR INTO THE STRUCTURE. >GARAGE DOOR, AND DRYWALL CEILING WAS FIRE DAMAGED, CEILING PARTIALLY REMOVED. THE NORTH AND SOUTH WALLS OF THE GARAGE HAD NO DRYWALL, ONLY INSULATION, AND THE EAST WALL BEING FIRE RATED DRYWALL WAS ONLY SMOKE DAMAGED. >THE STUDS IN THE NORTH WALL OF THE GARAGE WERE FIRE DAMAMGED AND WILL NEED TO BE REPLACED AS WELL AS THE T-111 SIDING. >THE ELECTRICAL WIRING AND OUTLETS IN THE NORTH WALL WERE FIRE DAMAGED AS WELL AS THE LIGHT FIXTURES AND WIRING THRU OUT THE CEILING. >ON THE NORTH WALL WAS THE HOTWATER HEATER, A REFRIGERATOR, A DRYER, AND THE HEATING/ COOLING UNIT WHICH WAS ON A SEPERATE DISCONNTECT. ADDITIONAL CIRCUITS MAY BE REQUIRED FOR THE REFREIGERATOR AND DRYER. >GARAGE DOOR AND MOTOR WERE ALSO FIRE DAMAGED >THERE WERE TWO CARS ONE BLACK MERCEDES VAN, THE OTHER A SILVER MERCEDES SEDAN. POSSIBLE FIRE AND SMOKE DAMAGE TO BOTH. >CONTENTS INSIDE THE GARAGE WERE ALSO FIRE DAMAGED. > GARAGE DOOR WAS DOWN AND LOCKED, BOARD UP WAS CONTACTED TO SECURE THE WINDOWS IN THE TOP PANEL THAT WERE MELTED AND HAD FALLEN OUT. GARAGE DOOR THAT ENTERED THE HOUSE WAS INSIDE THE STRUCTURE. OCCUPANTS WERE RECEIVING HELP FROM FAMILY AND WILL BE STAYING WITH FAMILY AND RED CROSS NOT REQUIRED. OCCUPANTS ASKED IF THEY COULD COME AND GO TO GET PERSONAL BELONGINGS, C/E HAS NO ISSUES WITH THEM COMING LATER TO GET BELONGINGS AS THEY NEEDE TO GET TO TWO CHILDREN WHO WERE TAKEN TO THE PARENTS. OWNER WAS CONTACTED, OWNER CONTACTED INSURANCE COMPANY. MY BUSINESS CARD AND NOV WAS SENT VIA TEXT MESSAGE TO THE OWNER. NOV WAS ISSUED FOR EMERGENCY VACATE BECAUSE OCCUPANTS NOW HAVE NO UTILITIES, AND PERMITS REQUIRED FOR ALL NECESSARY REPAIRS. C/E HAS NO FURTHER ISSUES. COMPLIANCE / CLOSE CASE. |