Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING

Entered Date:

09/14/2020

Applicant:

N/A

Description:

UNIT 216 CFIRE

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV06202
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/14/2020 INSP - INITIAL CODE ENFORCMENT BERMUDEZ Approved ON SITE; TFD ON SITE CASE NUMBER TFD2063838. TFD SHUT OFF ELECTRIC POWER TO ENTIRE BUILDING AS WELL AS WATER SUPPLY. CONFIRMED ADDRESS: 4809 E PIMA ST UNIT 216 OWNER/ OCCUPANT: MOUNTAIN TERRACE APARTMENTS LLC / DEBBIE TORRE/ MGR CRYSTAL IN UNIT 101. CAUSE OF DAMAGE: APARTMENT HOUSE FIRE LOCATION OF DAMAGE: KITCHEN AND LIVING ROOM BUILDING: THERE IS FIRE AND HEAVY SMOKE DAMAGE TO THE INTERIOR KITHCEN, LIVING ROOM AND HALLWAY WALLS, FLOORING, CEILING AND FLOORS, MULTIPLE TFD INSPECTIONS HOLES EXPOSING INSULATION AND WOOD FRAMING, VENT HOLES IN LIVING ROOM AND KITCHEN ROOFS, HEAVY SMOKE DAMAGE TO BEDROOM ONE, TFD INSPECTIONS HOLES, EXPOSING INSULATION AND WOOD FRAMING. HEAVY SMOKE DAMAGE TO BEDROOM TWO. HEAVY SMOKE AND HEAT DAMAGE TO EXTERIOR PORCH CEILING AND LIGHT FIXTURES. ELECTRICAL: THE FIRE DAMAGE ZONE HAS MULTIPLE ELECTRICAL DEVICES IN CLOSE PROXIMITY TO THE FIRE, THE INTERIOR KITCHEN, HALLWAY AND LIVING ROOMS ELECTRICAL WIRING, OUTLETS AND FIXTURES ARE MELTED. THE SERVICE PANEL IS MISSING A BREAHER AND HAS BEEN TURNED OFF. POWER WAS DISCONNECTED BY FIRE DEPT. TEP WILL ISOLATE APARTMENT AND EXTERIOR HALL CORRIDOR, KEEPING POWER OFF. PLUMBING: INTERIOR PLUMBING TO KITCHEN WAS IN CLOSE PROXIMITY TO FIRE DAMAGE ZONE, FIRE AND HEAT DAMAGE. MECHANICAL: HEAVY SMOKE DAMAGE TO THE LIVING ROOM, KITCHEN, HALLWAY, BATHROOM AND BED ROOMS A/C VENTS. REMARKS: THIS HOME IS NOW CONDEMNED AND PERMITS ARE REQUIRED FOR REPAIRS. OWNER / PROPERTY MANAGEMENT WILL SECURE THE UNIT. TENANTS WILL BE PLACED BY AMERICAN RED CROSS. ELECTRIC POWER RESTORED TO ALL UNIT ISOLATING UNIT 216 AND 116. WATER SUPPLY RESTORED TO ALL UNITS. POSTED UNSAFE TO OCCUPY PLACARD.
07/19/2021 INSP - FOLLOW UP CODE ENFORCE BERMUDEZ Approved PERMIT T20CM08314 FINALED FOR ALL REPAIRS DUE TO FIRE. WILL CLOSE CASE AT THIS TIME.

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T20DV06202
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
09/14/2020 CONTACTED IN PERSON
09/14/2020 RED CROSS / PRIMAVERA
09/14/2020 NOTICE AND ORDER ISSUED
09/14/2020 NOTICE OF VIOLATION ISSUED
07/19/2021 VIOLATION CLOSED
09/14/2020 STRUCTURE SECURED BY ???
09/14/2020 8-5 CITY COMM EMERGENCY