Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T20DV05806
Case Details
Entered Date:
08/22/2020
Applicant:
RAMIRO GORDILLO MENDEZ & FIDELFA BAUTISTA GARCIA CP/RS
Description:
RESIDENTIAL FIRE
Outstanding Inspections
Case Number: T20DV05806
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T20DV05806
Case Description: EMERGENCY
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/25/2020 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED SITE, MET WITH TFD INVESTIGATORS AND FIREFIGHTERS. I HAD BEEN TO THE PROPERTY BEFORE IT WAS A YARD SALERS HOME. THEY PICK UP SALABLE BELONGINGS AND RESELL THEM. UPON ARRIVAL FOUND THE SMALL CARPORT AREA HAD BEEN COMPLETELY BURNED AND ALL CONTENTS INSIDE ALSO BURNED. BEHIND THE CARPORT WAS A METAL AWNING APPROX 40 FT X 45 FT THAT WAS ALSO FILLED WITH YARD SALE BELONGINGS AND ALL CONTENTS ALSO BURNED. THE FIRE MOVED INTO THE HOUSE FROM THE CARPORT. THE DINING ROOM AND KITCHEN RECEIVED FIRE DAMAGE ASLO HEAVY SMOKE DAMAGE. THE HALLWAY AND BATHROOM OFF THE KITCHEN ALSO RECEIVED FIRE DAMAGE AND HEAVY SMOKE DAMAGE. THE SERVICE PANEL HAD BEEN UPGRADED, THE INTERIOR WIRING WAS MIXED OLD AND NEW AND WAS LEFT EXPOSED FROM THE FIRE. SOME OUTLETS, SWITCHES, AND LIGHT FIXTURES WERE ALSO FIRE DAMAGED.BEDROOMS AND LIVINGROOM ALSO HEAVY SMOKE DAMAGE. >TFD HAD TURNED ALL POWER OFF AND ASKED TEP TO LOCK OUT THE METER. >S/W GAS REPORTED NO GAS SINCE 2018, COMPLETED A LINE TEST AND EVERYTHING CHECKED OUT OK, WOULD CHECK TO SEE IF SUPERVISION WANTED THE METER REMOVED. >HOMEOWNER HAD 5/8" PLYWOOD IN THE REAR YARD AND SECURED THE FRONT CARPORT OPENING. THERE WAS FENCE AND BLOCK WALL THAT COMPLETELY SURROUNDED THE REAR YARD AREA. TWO GATES WERE LOCKABLE. OWNER STATED HE WOULD LOCK THE FRONT DOOR TO THE HOUSE. >TFD HAD CONTACTED RED CROSS TO HOUSE THE OCCUPANTS. TFD ALSO LEFT ENGINE 11 TO STAY BEHIND PUT OUT ANY HOTSPOTS AS REAR AWNING CONTINUED TO HAVE SMALL FLARE UPS. >C/E ISSUED EMERGENCY VACATE, PERMITS REQUIRED NOV'S AND INDEMNIFICATION PAPERWORK. PROPERTY WAS SECURED AND OCCUPANTS WAITING FOR RED CROSS AT THE TIME OF OUR EXIT. ALL ISSUES HAD BEEN ADDRESSED. COMPLIANCE / CLOSE CASE. |