Case: T20DV05805
Case Details
Entered Date:
08/22/2020
Applicant:
CAMPBELL 7 LLC
Description:
ELECTRICAL FIRE/ STE 116
Outstanding Inspections
Case Number: T20DV05805
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T20DV05805
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/25/2020 | INSP - INITIAL CODE ENFORCMENT | BERMUDEZ | Approved | ON SITE; WITH SENIOR INSPECTOR GGOODMAN FOR ON CALL TRAINING. |
08/25/2020 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED, SITE A SMALL U-SHAPED STRIP WITH A DENTAL OFFICE THAT TOOK UP 3 SUITES ON THE SOUTH SIDE. TFD STATED THERE WAS A FIRE IN THE BATHROOM ON THE EAST SIDE OF THE STRUCTURE. UPON ARRIVAL TF TURNED ALL POWER OFF TO THE ENTIRE STRIP MALL. THERE WAS A DROPPED CEILING THRU OUT THE BUILDING AND A E FT SPACE FROM THE DROPPED CEILING TO THE BOTTOM OF THE LPI RAFTER JOISTS. ALL ELECTRICAL, PLUMBING AND MECHANICAL RAN THRU THAT SPACE. THERE WAS A LOW VOLTAGE LINE THAT WAS SUSPECT AND A JUNCTION BOX THAT HAD ALL ELECTRICAL WIRING COMING OUT OF THE BOX THAT HAD BEEN CUT OFF, ADD THE BATHROOM FAN THAT WAS COMPLETELY BURNED UP AND THE DUCT COMING OFF THE DUCT WORK THAT ELBOWED UP TO THE CEILING EXIT. IT APPEARED THAT FIRE COMING OUT OF THE DUCT WORK SHOT STRAIGHT THRU THE SIDE OF THE DUCT BURNING STUDS AND TRIMMERS, THE STYROFOAM FOR THE STUCCO AND THE STUCCO WIRING. IT TOOK INVESTIGATORS SOME TIME TO CHECK ALL THE POSSIBLITIES. WHEN COMPLETED I WALKED ALL THE SERVICE PANELS TO ALL SUITES AND RESTORED POWER TO ALL OUTSIDE SUITES. WE THEN CHECKED TWO INTERIOR SUB PANELS, RESTORED POWER TO THE SOUTH SUB PANEL, TURNED BEAKERS ON ONE BY ONE, WALKED THE RESTORED SOUTH PORTION OF THE OFFICE. CHECKED SUB PANEL FOR THE NORTH SIDE OF THE OFFICE. FOUND ONE BREAKER HAD KICKED AD LEFT THAT OFF. TURNED POWER BACK ON TO THE SERVICE PANEL THAT SERVED THE NORTH SIDE OF THE OFFICE SUITES, TURNED BREAKERS ON ONE BY ONE AND LEAVING THE KICKED BREAKER OFF. WE WERE ABLE TO RESORE POWER TO THE OFFICE. INFORMED AND WALKED THE SUITES WITH THE OFFICE MANGER TURNED OFF ALL LIGHTS THAT WERE ON TO THE DENTAL OFFICES AND ISSUED A NOV FOR PERMITS REQUIRED WHICH WAS SIGNED FOR BY THE OFFICE MANAGER WHO WAS UNABLE TO GET AHOLD OF THE REGIONAL SUPERVISOR AS THEY HAVE 6 STORES IN TUCSON, 7 IN PHOENIX. MANAGER TRIED SEVERAL TIMES TO CONTACT REGIONAL MANAGER BUT STATED SHE WOULD NEED TO TRY LATER IN THE MORNING. NOV ISSUED AND SIGNED FOR BY THE MANAGER, SUITES WERE LOCKED UP BY THE MAINTANENCE PERSON. ALL ISSUED WERE ADDRESSED WHILE ON SITE. COMPLIANCE / CLOSE CASE. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T20DV05805
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date | Name |
09/03/2020 | CONTACTED BY MAILING |
09/03/2020 | NOTICE OF VIOLATION ISSUED |