Case Details

Status:

COMPLIAN

Type:

PROP MAINT MULTIPLE TYPES
Address:

Entered Date:

07/02/2020

Applicant:

RUBEN BEGLARYAN

Description:

TPD ONSITE water damage / structural issue

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV04527
Case Description: PROP MAINT MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/02/2020 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE THERE WERE TWO UNITS AFFECTED. THE SECOND FLOOR APT AT #1205 DID HAVE A MINOR FLOODING ISSUE AND THE FLOORING IN THE BATHROOM, KITCHEN, AND ONE OF THE BEDROOMS WAS VERY SOFT ESPECIALLY IN THE BATHROOM AROUND THE TOILET. I SPOKE WITH THE OCCUPANT WHO STATED HE WAS CURRENT ON RENT AND PAID RENT EVERY MONTH AND PAID EACH MONTH THE MONTH PRIOR. HE HAD INFORMED MANAGEMENT ABOUT THE BATHROOM AREA JUST RECENTLY. I WALKED THE APT WITH THE TUCSON REGION MANAGER AND FOUND THE SUB FLOORING TO BE SOFT AND BUCKLED THRU OUT THE UNIT. MANAGER STATED THEY DID HAVE A UNIT #1101 THAT THEY WOULD LIKE TO PUT HIM IN BUT WOULD NOT BE READY UNTIL TOMORROW. THE OCCUPANT AGREED IF HE COULD ALSO HAVE MANAGEMENT HELP HIM MOVE HIS BIG ITEMS. OCCUPANT ALSO CALLED TEP TO HAVE POWER TRANSFFERED TO THE UNIT TO HELP MAKE THE MOVE SMOOTHER. A NOV FOR A EMERGENCY VACATE WAS ISSUED AND ALL PREPERATION AGREED UPON BY THE MANAGEMENT AND OCCUPANT. IT WAS NOTED ON THE NOV THAT THE OCCUPANT WAS MOVING INTO UNIT 1101. THE 2ND UNIT INVOLVED WAS UNIT 1105 AND UNIT HAD MINOR ISSUES. THAT MANAGEMENT AGREED TO ABATE AFTER WALKING THE UNIT WITH ME. MANAGEMENT HAD THE UNIT SPRAYED FOR MICE AND ROACHES. PESTCONTROL TOLD MANAGEMENT AND OCCUPANT THEY WOULD NEED TO HAVE THE BASEBOARD REMOVED TO DUE A THOROUGH JOB. MANAGER AREED TO REMOVE THE BASEBOARD THE FOLLOWING MONDAY AND SPRAY ON TUESDAY. THERE WERE ALSO WATER ISSUES IN THE CEILING OF THE BATHROOM, ONE COULD SEE WHERE A PATCH WAS COMPLETED BUT SAGGING, I ASKED THAT THE PATCH BE RESCREWED TO THE CEILING AND RETEXTURED TO MATCH THE ORIGINAL CEILING. IN THE N/E BEDROOM THERE WERE POSSIBLE SIGNS OF LEAKING NEAR THE CORNER WALL/ CELING AND I ASKED THEY CUT A 2FT X 4FT OPENING TO DETERMINE IF THERE IS NEW WATER DAMAGE OR IF IT IS OLD DAMMAGE AND REPLACE DRYWALL ACCORDINGLY, TAPE AND TEXTURE TO MATCH EXISITING. OWNER ALSO STATED THAT THE FRONT DOOR WAS MISSING A THRESHOLD. I SPOKE WITH OCCUPANTS ABOUT HELPING WITH KEEPING UNIT CLEAN AND WORKING WITH MAINTANENCE WHEN WORK BEGINS. TPD AND TUCSON REGIONAL MANGER WAS PRESENT WHEN ALL CONVERSATION TOOK PLACE. NOV WAS ISSUED FOR ALL REPAIRS MENTIONED ABOVE AND TO TAKE PLACE WITHIN 21 DAYS.
07/20/2020 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved FOLLOW UP INSPECTION FOR UNIT 1205 FOUND THAT OCCUPANTS HAD BEEN PLACED IN A MOTEL, BASEBOARD WAS REMOVED FROM ALL WALLS AND UNIT WAS SPRAYED. BASEBOARDS WERE RESECURED. CEILING IN THE BATHROOM WAS PROPERLY SECURED, TAPED TEXTURED AND PAINTED, BATHROOM DOOR WAS REPAIRED SO IT CLOSED PROPERLY. CEILING IN THE BEDROOM WAS REMOVED AND CHECKED, NO LEAKING FOUND IN THE AREA, DRYWALL WAS REPLACED TAPED AND TEXTURED. THE FRONT DOOR HAD THE TRESHOLD REPLACED. ALL ISSUES HAVE BEEN ABATED AND OK'ED BY THE TENANT. COMPLIANCE / CLOSE CASE.