Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE
Address:

Entered Date:

06/18/2020

Applicant:

DUANE A & DIANA L GROTHE CP/RS

Description:

HOUSE FIRE

Outstanding Inspections

Case Number: T20DV04245
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV04245
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 1
End Date Description Inspector Results Comments
06/18/2020 INSP - INITIAL CODE ENFORCMENT MORALES Approved EMERGENCY CALL OUT BY TFD: THERE IS SEVERE FIRE DAMAGE TO THE ATTACHED UTILITY ROOM, ALL STRUCTURAL MEMBERS, RAFTERS, WALL STUDS, DECKING AND ROOF AND WALL SHEATHING HAVE DEEP CRACKS WITH CHARRING ON THE SURFACE OF ALL MEMBERS. THE RAFTER DAMAGE SPANS TO WHERE THE RAFTER BEARS ON THE BEARING WALL, NO DAMAGE BEYOND THAT POINT. MULTIPLE RAFTERS AND ROOF DECKING OUTSIDE OF THE UTILITY ROOM ZONE WERE DAMAGED BY FIRE. THE INTERIOR DAMAGE IN THE KITCHEN WHICH ABUTS THE UTILITY ROOM IS TO THE ENTIRE CEILING SHEETROCK AND INSULATION. WATER DAMAGED AREA. THE KITCHEN PARTY WALL IS WOOD FRAME 2 X 4 WALL WITH DAMAGE TO THE SHEETROCK, CLEARLY VISIBLE FROM EACH ADJOINING UNIT. THE HALLWAY ALSO CEILING SHEET ROCK DAMAGE SPANNING 3 FEET BY 10 FEET. LIVING ROOM HAS ONE SMALL (UNDER 1 FOOT) INSPECTION HOLE IN CEILING. THE FRONT DOOR JAM WAS DAMAGED DUE TO A FORCED ENTRY BY TFD. ELECTRICAL: THE 2 PACK MAIN DISCONNECT WAS ATTACHED TO THE UTILITY ROOM THE DISCONNECT HAS SEVERE HEAT DAMAGE. INSIDE THE UTILITY ROOM WAS AN ELECTRICAL DISTRIBUTION PANEL SEVERELY BURNT WITH BARE AND EXPOSED WIRING SPANNING INTO THE INTERIOR KITCHEN AREA. THE KITCHEN AREA HAS HEAT DAMAGE TO ALL ELECTRICAL DEVICES. TEP DID DISCONNECT POWER AD REMOVED BOTH METERS. PLUMBING: THE UTILITY ROOM HAS A GAS FIRE WATER HEATER AND AN ELECTRIC WASHER AND DRYER THESE APPLIANCES ARE DAMAGED. THE ABS VENT PIPE ALSO DAMAGED. WATER WAS SHUT OFF. SWG DID PIN BOTH METERS OFF. MECHANICAL: MILD SMOKE THROUGH OUT THE INTERIOR. REMARKS: THE UNIT WAS CONDEMNED AND ORDERED TO VACATE, PERMIT IS REQUIRED FOR REPAIRS. OWNER TO SECURE THE BUILDING.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T20DV04245
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
06/19/2020 CONTACTED IN PERSON
06/19/2020 NOTICE OF VIOLATION ISSUED

Documents

File Name Document Type  
4151 E ELIDA ST.DOC DOCUMENTS VIEW
4151 E ELIDA ST.PDF DOCUMENTS VIEW