Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

06/05/2020

Applicant:

TANQUE VERDE HOLDINGS LLC

Description:

COMMUNICATION CALLED THAT T.F.D. ON SITE WITH A CAR INTO BUILDING, F201570238

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV03940
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/05/2020 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Communication called that T.F.D. on site with a car into building. Arrived and the units were still on site. The car has hit a masonry wall on the exterior of the property and into the house in the living room area. The wall is a wood frame wall with chicken wire and a one coat system of stucco. The interior wall is drywall. The stucco is able to see into the house from the impact. The wall has 2-windows and the trimmers and king studs in the middle of the windows have been pushed into the house approx. 3" and off the bottom plate. The wall has electrical and some low voltage wiring in the wood studs. Some of the cripples have broken or split on the window. The drywall has fallen on the bottom of the window and has cracking on the edges of the windows. The stucco has some cracking on the upper portion of the corners of the windows. The electrical is all working and nothing has been turned off to the unit. The windows are all working and has a sliding glass door and also working at this time. Not able to make contact with the property manager and called Arcaide Industries to have the area secured. The tenant will be able to remain in the unit and will have to check to remain when the repairs start. RV.
06/12/2020 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved The unit is secured and still being occupied. The tenant is trying to get another unit to moved to. The complex will be working with the insurance company and getting a contractor to do the work. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T20DV03940
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
06/05/2020 NOTICE OF VIOLATION ISSUED
06/05/2020 STRUCTURE SECURED BY ???