Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING
Address:

Entered Date:

02/28/2020

Applicant:

570 W PRINCE LLC ATTN: SCOTT BRITTENHAM

Description:

2 alarm fire

Outstanding Inspections

Case Number: T20DV01518
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV01518
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/28/2020 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved THE UNITS HAVE BEEN SECURED BY MANAGEMENT. ALL DOCUMENTS IN SIRE, CLOSE CASE
02/28/2020 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD: UNIT 31 BUILDING DAMAGE: UNIT LOCATED IN 1st FLOOR, WOOD FRAME, STUCCO FINISH EXTERIOR. THERE IS DAMAGE TO THE FOLLOWING: 3 X 5 BEDROOM WINDOW IS DAMAGED, ALL OF THE CEILING COVERING IN PATIO, PATIO CLOSET DOOR AND PATIO EXIT DOOR HAVE BEEN DESTROYED. THE PATIO'S 6 X 6 WOOD POSTED HAS DEEP CRACKS AND IS BURNT. MULTIPLE INSPECTION HOLES IN THE LIVING AND BEDROOM. WATER DAMAGE TO ALL ROOMS IN WALLS CEILING AND FLOORING. 4 RAFTERS INSIDE THE PATIO CLOSET HAVE SEVER FIRE DAMAGE ALONG WITH THE INTERIOR WALLS. THE DRYWALL ABOVE THE PATIO EXIT DOOR HAS FIRE DAMAGE ELECTRICAL: ELECTRICAL DEVICES ARE WET IN ALL ROOMS, THE DEVICES AROUND THE PATIO EXIT DOOR BOTH INTERIOR AND EXTERIOR HAVE HEAT DAMAGE. TEP DISCONNECT POWER. PLUMBING: N/A MECHANICAL: SMOKE DAMAGE TO ALL ROOMS REMARKS: UNIT 31 WAS CONDEMNED, PERMITS REQUIRED, MANAGEMENT WILL SECURE THE UNIT TODAY. UNIT 32: BUILDING DAMAGE: UNIT LOCATED IN 2ND STORY, WOOD FRAME, STUCCO FINISH EXTERIOR. THERE IS DAMAGE TO THE FOLLOWING: 3 X 5 BEDROOM WINDOW, 2 X 8 CEILING COVERING IN PATIO, WATER DAMAGE TO LIVING, KITCHEN AND BEDROOM FLOORING AND WALLS. ELECTRICAL: ELECTRICAL DEVICES ARE WET IN LIVING, BATH, KITCHEN AND BEDROOM. TEP DISCONNECT POWER. PLUMBING: N/A MECHANICAL: N/A REMARKS: UNIT 32 WAS CONDEMNED, PERMITS REQUIRED, MANAGEMENT WILL SECURE THE UNIT TODAY UNIT 33, BUILDING DAMAGE: UNIT LOCATED IN 1st FLOOR, WOOD FRAME, STUCCO FINISH EXTERIOR. THERE IS DAMAGE TO THE FOLLOWING: 3 X 5 BEDROOM WINDOW IS DAMAGED, ALL OF THE CEILING COVERING IN PATIO, PATIO CLOSET DOOR AND PATIO EXIT DOOR HAVE BEEN DESTROYED. THE PATIO'S 6 X 6 WOOD POSTED HAS DEEP CRACKS AND IS BURNT. MULTIPLE INSPECTION HOLES IN THE BEDROOM. WATER DAMAGE TO ALL ROOMS IN WALLS CEILING AND FLOORING. ELECTRICAL: ELECTRICAL DEVICES ARE WET IN ALL ROOMS, THE DEVICES AROUND THE PATIO EXIT DOOR BOTH INTERIOR AND EXTERIOR HAVE HEAT DAMAGE. THE BEDROOM SMOKE ALARM HAS MELTED TEP DISCONNECT POWER. PLUMBING: N/A MECHANICAL: SMOKE DAMAGE TO ALL ROOMS REMARKS: UNIT 33 WAS CONDEMNED, PERMITS REQUIRED, MANAGEMENT WILL SECURE THE UNIT TODAY UNIT 34: BUILDING DAMAGE: UNIT LOCATED IN 2ND STORY, WOOD FRAME, STUCCO FINISH EXTERIOR. THERE IS DAMAGE TO THE FOLLOWING: 3 X 5 BEDROOM WINDOW, 2 X 8 CEILING COVERING IN PATIO, PATIO CLOSET DOOR, 4 X 7 SLIDER DOOR TO PATIO, MULTIPLE INSPECTION HOLES IN THE BEDROOM. WATER DAMAGE TO ALL ROOMS IN WALLS CEILING AND FLOORING. ELECTRICAL: ELECTRICAL DEVICES ARE WET IN ALL ROOMS. BEDROOM HAS MELTED CEILING LIGHT FIXTURE AND A SMOKE ALARM, TEP DISCONNECT POWER. PLUMBING: N/A MECHANICAL: SMOKE DAMAGE TO ALL ROOMS REMARKS: UNIT 34 WAS CONDEMNED, PERMITS REQUIRED, MANAGEMENT WILL SECURE THE UNIT TODAY. INSPECTOR: JUAN VALDEZ DATE 2/28/2020 ALL UNIT WERE CONDEMNED, PERMIT ARE REQUIRED FOR REPAIRS, MANAGEMENT DID SECURE THE UNITS,

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T20DV01518
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
02/28/2020 CONTACTED IN PERSON
02/28/2020 NOTICE AND ORDER ISSUED
02/28/2020 VIOLATION CLOSED
02/28/2020 STRUCTURE SECURED BY ???
02/28/2020 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
DAMAGE REPORT 2019 570 W PRINCE 31.DOC DOCUMENTS VIEW
DAMAGE REPORT 2019 570 W PRINCE 32.DOC DOCUMENTS VIEW
DAMAGE REPORT 2019 570 W PRINCE 33.DOC DOCUMENTS VIEW
DAMAGE REPORT 2019 570 W PRINCE 34.DOC DOCUMENTS VIEW
20200226_201648.JPG DOCUMENTS VIEW
20200226_201712.JPG DOCUMENTS VIEW
20200226_201735.JPG DOCUMENTS VIEW
20200226_201742.JPG DOCUMENTS VIEW
20200226_201752.JPG DOCUMENTS VIEW
20200226_201824.JPG DOCUMENTS VIEW
20200226_201909.JPG DOCUMENTS VIEW
20200226_201916.JPG DOCUMENTS VIEW
20200226_201950.JPG DOCUMENTS VIEW
20200226_202208.JPG DOCUMENTS VIEW
20200226_202227.JPG DOCUMENTS VIEW
20200226_202232.JPG DOCUMENTS VIEW
20200226_202237.JPG DOCUMENTS VIEW
20200226_202251.JPG DOCUMENTS VIEW
20200226_202332.JPG DOCUMENTS VIEW
20200226_202349.JPG DOCUMENTS VIEW
20200226_202357.JPG DOCUMENTS VIEW
20200226_202411.JPG DOCUMENTS VIEW
20200226_202424.JPG DOCUMENTS VIEW
20200226_202521.JPG DOCUMENTS VIEW
20200226_213015.JPG DOCUMENTS VIEW
20200226_213023.JPG DOCUMENTS VIEW
20200226_213035.JPG DOCUMENTS VIEW
20200226_213901.JPG DOCUMENTS VIEW
20200228_094223.JPG DOCUMENTS VIEW
20200228_094231.JPG DOCUMENTS VIEW
20200228_094241.JPG DOCUMENTS VIEW
20200228_094316.JPG DOCUMENTS VIEW
20200228_094323.JPG DOCUMENTS VIEW
20200228_094507.JPG DOCUMENTS VIEW
20200228_094530.JPG DOCUMENTS VIEW
20200228_094555.JPG DOCUMENTS VIEW
20200228_094559.JPG DOCUMENTS VIEW
20200228_094608.JPG DOCUMENTS VIEW
20200228_101308.JPG DOCUMENTS VIEW
20200228_105105.JPG DOCUMENTS VIEW
20200228_105107.JPG DOCUMENTS VIEW
20200228_105110.JPG DOCUMENTS VIEW
20200228_105121.JPG DOCUMENTS VIEW
20200228_105124.JPG DOCUMENTS VIEW
20200228_105126.JPG DOCUMENTS VIEW
20200228_105135.JPG DOCUMENTS VIEW
20200228_105142.JPG DOCUMENTS VIEW
20200228_112141.JPG DOCUMENTS VIEW
20200228_112155.JPG DOCUMENTS VIEW
20200228_112202.JPG DOCUMENTS VIEW
20200228_120019.JPG DOCUMENTS VIEW
570 NOVS.PDF DOCUMENTS VIEW