Case: T20DV01518
Case Details
Entered Date:
02/28/2020
Applicant:
570 W PRINCE LLC ATTN: SCOTT BRITTENHAM
Description:
2 alarm fire
Outstanding Inspections
Case Number: T20DV01518
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T20DV01518
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/28/2020 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | THE UNITS HAVE BEEN SECURED BY MANAGEMENT. ALL DOCUMENTS IN SIRE, CLOSE CASE |
| 02/28/2020 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | EMERGENCY CALL OUT BY TFD: UNIT 31 BUILDING DAMAGE: UNIT LOCATED IN 1st FLOOR, WOOD FRAME, STUCCO FINISH EXTERIOR. THERE IS DAMAGE TO THE FOLLOWING: 3 X 5 BEDROOM WINDOW IS DAMAGED, ALL OF THE CEILING COVERING IN PATIO, PATIO CLOSET DOOR AND PATIO EXIT DOOR HAVE BEEN DESTROYED. THE PATIO'S 6 X 6 WOOD POSTED HAS DEEP CRACKS AND IS BURNT. MULTIPLE INSPECTION HOLES IN THE LIVING AND BEDROOM. WATER DAMAGE TO ALL ROOMS IN WALLS CEILING AND FLOORING. 4 RAFTERS INSIDE THE PATIO CLOSET HAVE SEVER FIRE DAMAGE ALONG WITH THE INTERIOR WALLS. THE DRYWALL ABOVE THE PATIO EXIT DOOR HAS FIRE DAMAGE ELECTRICAL: ELECTRICAL DEVICES ARE WET IN ALL ROOMS, THE DEVICES AROUND THE PATIO EXIT DOOR BOTH INTERIOR AND EXTERIOR HAVE HEAT DAMAGE. TEP DISCONNECT POWER. PLUMBING: N/A MECHANICAL: SMOKE DAMAGE TO ALL ROOMS REMARKS: UNIT 31 WAS CONDEMNED, PERMITS REQUIRED, MANAGEMENT WILL SECURE THE UNIT TODAY. UNIT 32: BUILDING DAMAGE: UNIT LOCATED IN 2ND STORY, WOOD FRAME, STUCCO FINISH EXTERIOR. THERE IS DAMAGE TO THE FOLLOWING: 3 X 5 BEDROOM WINDOW, 2 X 8 CEILING COVERING IN PATIO, WATER DAMAGE TO LIVING, KITCHEN AND BEDROOM FLOORING AND WALLS. ELECTRICAL: ELECTRICAL DEVICES ARE WET IN LIVING, BATH, KITCHEN AND BEDROOM. TEP DISCONNECT POWER. PLUMBING: N/A MECHANICAL: N/A REMARKS: UNIT 32 WAS CONDEMNED, PERMITS REQUIRED, MANAGEMENT WILL SECURE THE UNIT TODAY UNIT 33, BUILDING DAMAGE: UNIT LOCATED IN 1st FLOOR, WOOD FRAME, STUCCO FINISH EXTERIOR. THERE IS DAMAGE TO THE FOLLOWING: 3 X 5 BEDROOM WINDOW IS DAMAGED, ALL OF THE CEILING COVERING IN PATIO, PATIO CLOSET DOOR AND PATIO EXIT DOOR HAVE BEEN DESTROYED. THE PATIO'S 6 X 6 WOOD POSTED HAS DEEP CRACKS AND IS BURNT. MULTIPLE INSPECTION HOLES IN THE BEDROOM. WATER DAMAGE TO ALL ROOMS IN WALLS CEILING AND FLOORING. ELECTRICAL: ELECTRICAL DEVICES ARE WET IN ALL ROOMS, THE DEVICES AROUND THE PATIO EXIT DOOR BOTH INTERIOR AND EXTERIOR HAVE HEAT DAMAGE. THE BEDROOM SMOKE ALARM HAS MELTED TEP DISCONNECT POWER. PLUMBING: N/A MECHANICAL: SMOKE DAMAGE TO ALL ROOMS REMARKS: UNIT 33 WAS CONDEMNED, PERMITS REQUIRED, MANAGEMENT WILL SECURE THE UNIT TODAY UNIT 34: BUILDING DAMAGE: UNIT LOCATED IN 2ND STORY, WOOD FRAME, STUCCO FINISH EXTERIOR. THERE IS DAMAGE TO THE FOLLOWING: 3 X 5 BEDROOM WINDOW, 2 X 8 CEILING COVERING IN PATIO, PATIO CLOSET DOOR, 4 X 7 SLIDER DOOR TO PATIO, MULTIPLE INSPECTION HOLES IN THE BEDROOM. WATER DAMAGE TO ALL ROOMS IN WALLS CEILING AND FLOORING. ELECTRICAL: ELECTRICAL DEVICES ARE WET IN ALL ROOMS. BEDROOM HAS MELTED CEILING LIGHT FIXTURE AND A SMOKE ALARM, TEP DISCONNECT POWER. PLUMBING: N/A MECHANICAL: SMOKE DAMAGE TO ALL ROOMS REMARKS: UNIT 34 WAS CONDEMNED, PERMITS REQUIRED, MANAGEMENT WILL SECURE THE UNIT TODAY. INSPECTOR: JUAN VALDEZ DATE 2/28/2020 ALL UNIT WERE CONDEMNED, PERMIT ARE REQUIRED FOR REPAIRS, MANAGEMENT DID SECURE THE UNITS, |
Completed Activity Special Conditions
Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T20DV01518
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 02/28/2020 | CONTACTED IN PERSON |
| 02/28/2020 | NOTICE AND ORDER ISSUED |
| 02/28/2020 | VIOLATION CLOSED |
| 02/28/2020 | STRUCTURE SECURED BY ??? |
| 02/28/2020 | 8-5 CITY COMM EMERGENCY |