Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

CONDEMNATION

Entered Date:

02/26/2020

Applicant:

CLIFFORD L MOES II

Description:

DWELLING CONDEMNED

Outstanding Inspections

Case Number: T20DV01469
Case Status: COMPLIAN
Case Description: CONDEMNATION
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV01469
Case Description: CONDEMNATION
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/26/2020 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TPD: THE SINGLE CAR CARPORT HAS COLLAPSED IN THE FRONT YARD, OWNER STATED IT HAPPENED OVER 2 MONTHS AGO. THE REAR DOOR IS DAMAGED. I SPOKE TO THE OWNER AND HE DID GRANT PERMISSION TO ENTER THE DWELLING DUE TO TPD CONCERNS ON LIFE SAFETY. THERE IS MULTIPLE AREAS IN THE HALLWAY AND OTHER ROOMS WITH DAMAGE OR MISSING PIECES OF CEILING DRYWALL. THE ROOF MEMBERS AND DECKING HAVE WATER STAINS, THE HALLWAY DOES HAVE CONTAINERS WITH WATER. THE LIVING ROOM IS NOT ACCESSIBLE DO TO THE AMOUNT OF MISCELLANEOUS ITEMS BLOCKING ACCESS FROM THE FRONT DOOR AND KITCHEN. THE MASTER AND SPARE BED ROOMS HAVE STORAGE BLOCKING WINDOWS AND PROHIBIT RAPID EGRESS, THERE IS ALSO A MOUNTAIN OF USED NAPKINS AND OTHER WASTE PAPER PRODUCTS IN THESE ROOMS WITH SPACE HEATERS ON, UNABLE TO SEE WHERE ONE OF THE HEATER CONNECTS, THE OTHER SPACE HEATER IS BEING POWERED BY EXTERIOR CORDS. THE HALLWAY HAS PORTABLE FANS CONNECTED INTO EXTENSION CORDS. THE TWO BATHROOM ARE BLOCKED BY BOXES AND STORAGE, ONE OF THE BATHROOMS DOESN'T HAVE A COMMODE. THE KITCHEN HAS THE COUNTER TOPS AND APPLIANCES COVERED WITH PAPER AND WASTE PRODUCTS, UNABLE TO THE TOP OF THE RANGE. THE FLOORS ARE COVERED WITH CARD BOARD, WASTE PRODUCTS AND USED NAPKINS, THIS ENVIRONMENT IS UNSANITARY AND DANGEROUS DUE TO ELECTRICAL EQUIPMENT BEING POWER BY EXTENSION CORDS ON A PERMANENT BASES. THESE HEATERS HAVE COMBUSTIBLES IN CLOSE PROXIMITY TO THE CORDS AND HEATERS, UNABLE TO SEE OUTLETS IN THE ROOMS DUE TO STORAGE, EGRESS IS BLOCKED AND EXTERIOR BEDROOM WINDOW HAVE GRATES WITH PED LOCKS LOCKED FROM THE EXTERIOR . THE CITY DID ORDER THE DWELLING CONDEMNED AND THE POWER WAS DISCONNECT BY TEP. MULTIPLE FENCE PANELS WERE ERECTED AROUND THE COLLAPSED CARPORT. RESTRICTIONS ARE AS FOLLOWS: NO ONE IS ALLOWED TO WORK ON DWELLING OR PROPERTY AT NIGHT
05/01/2020 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved CLOSE CASE INSP MENDOZA HAS OPENED CASE TO ADDRESS THE CODE VIOLATIONS T20DV02070

Completed Activity Special Conditions

Case Description - CONDEMNATION
Case Number - T20DV01469
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
02/26/2020 CONTACTED IN PERSON
02/26/2020 NOTICE AND ORDER ISSUED
02/26/2020 VIOLATION CLOSED
08/06/2020 SEC LEIN PLACED ON PROPERTY IN THE AMOUNT OF ???
02/26/2020 STRUCTURE SECURED BY ???
02/26/2020 CALLBACK

Documents

File Name Document Type  
SCAN.PDF DOCUMENTS VIEW
20200226_201625.JPG DOCUMENTS VIEW
20200226_201631.JPG DOCUMENTS VIEW
20200226_201648.JPG DOCUMENTS VIEW
20200226_201712.JPG DOCUMENTS VIEW
20200226_201735.JPG DOCUMENTS VIEW
20200226_201742.JPG DOCUMENTS VIEW
20200226_201752.JPG DOCUMENTS VIEW
20200226_201824.JPG DOCUMENTS VIEW
20200226_201909.JPG DOCUMENTS VIEW
20200226_201916.JPG DOCUMENTS VIEW
20200226_201950.JPG DOCUMENTS VIEW
20200226_202208.JPG DOCUMENTS VIEW
20200226_202227.JPG DOCUMENTS VIEW
20200226_202232.JPG DOCUMENTS VIEW
20200226_202237.JPG DOCUMENTS VIEW
20200226_202251.JPG DOCUMENTS VIEW
20200226_202332.JPG DOCUMENTS VIEW
20200226_202349.JPG DOCUMENTS VIEW
20200226_202357.JPG DOCUMENTS VIEW
20200226_202411.JPG DOCUMENTS VIEW
20200226_202424.JPG DOCUMENTS VIEW
20200226_202521.JPG DOCUMENTS VIEW
20200226_213015.JPG DOCUMENTS VIEW
20200226_213023.JPG DOCUMENTS VIEW
20200226_213035.JPG DOCUMENTS VIEW
20200226_213901.JPG DOCUMENTS VIEW