Case: T20DV00948
Case Details
Entered Date:
02/10/2020
Applicant:
MAI GILLIAM
Description:
Unti 3 - Unsanitary and uninhabitable. Electrical issues throughout unit, smoking outlets. Cords running throughout rooms due to outlets not working (no electric in bedrooms). Roof leaks. No heat, baseboards heaters attached to walls, no electric to walls.
Case Violations
Case Number: T20DV00948
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 02/18/2020 | REFERENCE |
| 02/18/2020 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 02/18/2020 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 02/18/2020 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 02/18/2020 | T.C. Ch. 16, Sec. 16-11(f)(6) All repair work shall be done in a workman like manner. |
Outstanding Inspections
Case Number: T20DV00948
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
| NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
| NPO(HC)-HEATING & VENTILATION | None | Not Inspected | ||
| NPO - SMOKE ALARMS | None | Not Inspected | ||
| NPO - EXT. BUILDING MAINTENANC | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T20DV00948
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/18/2020 | INSP - INITIAL CODE ENFORCMENT | MENDOZA | Approved | LARGE GAPS IN THE FRONT AND KITCHEN EXTERIOR DOORS THUS NOT PREVENTING INSECTS, RODENTS AND MOISUTURE FROM INTRUDING TO THE INTERIOR OF THE DWELLING MISSING SMOKE DETECTORS THROUGHOUT THE UNIT MAIN ELECTRICAL SERVICE PANEL LACKS PROPERER LABELING SOUTHWEST BEDROOM OUTLET HAS MELTED AND BURNT(ELECTRICAL TERMINATED) LIVING ROOM AND SOUTHWEST WALL HEATERS LACK DEDICATED CIRCUIT AND ARE CONNECTED TO BEDROOM CIRCUIT THAT HAS BURNED THUS UNIT HAS LACKED HEAT. KITCHEN GFCI OUTLETS DO NOT ALLOW FOR PROPER GROUNDED OUTLETS TO BE UTILIZED BATHROOM GFCI DOES NOT OPERATE AS INTENDED. WILL NOT DISCONNECT UNDER OVERLOAD 220 OUTLET IN WASHER AREA IS INOPERABLE |
| 03/10/2020 | INSP - FOLLOW UP CODE ENFORCE | MENDOZA | Approved | ELECTRICAL PANEL LABELED. FLOOR HEATERS NOW ON DEDICATED CIRCUIT. DOORS REPAIRED |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T20DV00948
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 02/10/2020 | CONTACTED BY PHONE |
| 02/18/2020 | CONTACTED BY MAILING |
| 02/18/2020 | NOTICE OF VIOLATION ISSUED |
| 03/10/2020 | VIOLATION CLOSED |