Case Details

Status:

COMPLIAN

Type:

CAR THROUGH COMMERCIAL BUILDIN

Entered Date:

01/22/2020

Applicant:

NORTH PANTANO ASSOCIATES LLC ATTN CHRIS PEEBLES

Description:

CAR INTO BUILDING.

Case Violations

Case Number: T20DV00488
Case Status: COMPLIAN
Case Description: CAR THROUGH COMMERCIAL BUILDIN
Total Violations: 3
Violation Date Code Statue
01/22/2020 REFERENCE
01/22/2020 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
01/22/2020 T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (3) The building, structure or any portion thereof has been damaged by fire, earthquake, wind, flood or any other cause, to such an extent that the structural strength or stability thereof is materially less than it was before the damage and is less than the minimum requirements of the building code for new buildings of similar structure, purpose or location.

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV00488
Case Description: CAR THROUGH COMMERCIAL BUILDIN
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/22/2020 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved VEHICLE COLLIDED INTO A WALL OF A TWO STORY COMMERCIAL BUILDING. AREA OF DAMAGE IS APPROX 6 FEET WIDE AND 8 FEET VERTICAL. BLOCK WAS PUSHED INTO THE INTERIOR OFFICE SPACE APPROX 2 TO 3 FEET. HEAVY CRACKING OF BLOCK BELOW AN OVERHANG. CRACKING AT OVERHANG RUNS APPROX 3 FEET. ELECTRICAL CIRCUIT DAMAGED AT THE IMPACT AREA. CIRUCUIT WAS ISOLATED AND TERMINATED. AREA IMPACTED WAS AT THE STEEL FRAME WINDOW AND NOT ON THE SUPPORT POST. HEAVEY CRACKING OF ALL DRYWALL IN THE OFFICE AREA. PHOTOS TAKEN
05/13/2020 INSP - FOLLOW UP CODE ENFORCE MENDOZA Approved REPAIR HAS BEEN COMPLETED

Completed Activity Special Conditions

Case Description - CAR THROUGH COMMERCIAL BUILDIN
Case Number - T20DV00488
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
02/25/2020 CONTACTED BY PHONE
01/22/2020 CONTACTED BY MAILING
01/22/2020 NOTICE OF VIOLATION ISSUED
05/13/2020 VIOLATION CLOSED
01/22/2020 STRUCTURE SECURED BY ???

Documents

File Name Document Type  
IMG_20200122_130914.JPG IMAGES VIEW
IMG_20200122_130930.JPG IMAGES VIEW
IMG_20200122_130941.JPG IMAGES VIEW
IMG_20200122_131021.JPG IMAGES VIEW
IMG_20200122_131028.JPG IMAGES VIEW
IMG_20200122_131035.JPG IMAGES VIEW
IMG_20200122_131045.JPG IMAGES VIEW
IMG_20200122_133117.JPG IMAGES VIEW
IMG_20200122_133129.JPG IMAGES VIEW
IMG_20200122_133138.JPG IMAGES VIEW