Applicant:

TEN NORTH SWAN LLC/ OWNER: CLYDE BUZZARD

Description:

CAR INTO BUILDING

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV09548
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/29/2019 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, MET WITH TPD OFFICERS WHO STATED THE BLACK VEHICLE HAD ENTERED THE SOUTH WALL OF THE LUCKY WISHBONE, DRIVER HAD BEEN RACING AND LEFT THE SCENE BUT WAS LATER FOUND. CAR WAS NOT IDENTIFIABLE. OWNER WAS ON SITE AND EXPLAINED THAT THE BUILDING WAS A METAL STRUCTURE AND COMPLETED AROUND 2011. I ASKED THE QUESTION BECAUSE THE WALL APPEARED TO BE INFILL ON BOTH THE SOUTH AND WEST SIDES. OWNER STATED THAT THE CORNER POST DID CARRY TWO STRUCTURAL METAL BEAMS. THE 4-0 X 5-0 WINDOWS WERE INSTALLED ON TOP OF THE 3'-6" INFILL WALL AND TO THE METAL BEAM ON THE TOP. THE SOUTHWEST ROOM WAS A DINING AREA AND I FOUND NO ELECTRICAL OUTLETS IN THE ROOM APPROX. 15 FT X 15FT. THE ONLY ELECTRICAL WAS FOR THE LIGHTS ABOVE THE DROPPED CEILING. I CHECKED ALL THE ELECTRICAL CIRCUITS WITH THE OWNER AS THE SERVICE PANEL WAS LOCKED OUT DUE TO HOMELESS CONTINOUSLY GETTING INTO THE PANEL. FINDINGS AS FOLLOWS: >NO ELECTRICAL OUTLETS IN THE DINING ROOM INFILL WALLS. ELECTRICAL LIGHTING IN THE DROPPED ACOUSTICAL CEILING ABOVE >ALL REFRIGERATORS AND FREEZERS REMAINED ON. CONTACTED PIMA COUNTY HEALTH THRU COMMUNICATIONS AND I ASKED OWNER TO CALL THEIR CONTACT PERSON FOR PIMA COUNTY HEALTH, WHICH THEY DID. PIMA COUNTY DID NOT RESPOND IN THE TIME I COMPLETED MY INSPECTION AND BOARDING OF THE SOUTH WALL. >STRUCTURAL DAMAGE WAS TO THE INFILL SECTION OF BLOCK VENEER AND GLASS WALL BELOW THE STEEL BEAM. >OWNERS ASKED IF THEY COULD CONTINUE BUSINESS AND HAD ALL DEBRIS REMOVED FROM THE S/W DINING AREA BEFORE I COMPLETED MY INSPECTION AND BOARDING. THERE WERE NO IMMINENT HAZARDS, THE REMAINING PORTIONS OF THE STRUCTURE WERE IN GOOD CONDITION. THERE ARE 2 ADDITIONAL DINING AREAS IN THE STORE, THE REASON FOR PIMA COUNTY HEALTH. >CAR REMOVED BY GARY'S TOWING. >STRUCTURE SECURED BY BOARD UP, ARCADIAN INDUSTRIES. >NOV ISSUED FOR PERMITS REQUIRED. SIGNED FOR BY THE OWNER ** C/E HAS NO ISSUES WITH THE OWNER CONTINUING BUSINESS, IF THE DINING AREA IS SECTIONED OF SO THAT CUSTOMERS DO NOT ENTER THE AREA. I ASKED OWNERS TO CONTACT ME, ONCE PIMA COUNTY HEALTH INSPECTED THE STORE.
12/31/2019 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved RECEIVED A CALL FROM THE OWNER WHO STATED PIMA COUNTY HEALTH DEPTWAS OUT AND INSPECTED THE STORE. SHE CHECKED ALL COOKING EQUIPMENT, FREEZERS AND REFRIGERATORS AND THE S/W DINING AREA AND INFORMED THEM THAT THEY HAD NO ISSUES WITH THE THE COOKING EQUIPMENT OR REFRIGERATOR AND FREEZER BUT IF THEY WANTED TO OPEN THEY WOULD NEED TO SECTION OFF THE DINING AREA BY TAPING THE AREA OFF, USE TABLES OR CHAIRS TO CLOSE IT OFF SO THAT THE AREA COULD NOT BE ENTERED, WHICH IS WHAT I HAD EXPECTED BECAUSE THE OWNER HAD CLEANED THE AFFECTED AREA FREE OF ANY TRASH AND DEBRIS AND GLASS FROM THE WINDOW. C/E HAS NO FURTHER ISSUES. COMPLIANCE / CLOSE CASE.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T19DV09548
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
12/31/2019 NOTICE OF VIOLATION ISSUED