Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

12/21/2019

Applicant:

JS10 LLC ATTN SARAH D ELDRIDGE

Description:

HOUSE FIRE

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV09502
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/21/2019 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved THERE IS DAMAGE MAJOR DAMAGE TO TRUSSES AND SUPPORT MEMBERS. THERE IS DEEP CRACKING TO THESE AREAS IN THE FRONT AND CENTER OF THE DWELLING. TWO 4 X 4 WINDOW OPENINGS AND ONE DOOR OPENING IN THE FRONT ROOM HAVE DAMAGE. THE SIDE WOOD FRAMED PORCH HAS TWO 4 X 4 POSTS AND WOOD MEMBER WITH DEEP CRACKING, THE FRONT GABLE SIDING ALSO HAS AREAS WITH FIRE DAMAGE. NO ROOF INSPECTION WAS CONDUCTED. INTERIOR FRONT ROOM AND HALLWAY HAS NO DRYWALL COVER TO THE CEILING. ELECTRICAL: THE SERVICE HAS MELTED WIRING ALSO IN CLOSE PROXIMITY TO THE FIRE. THERE IS MELTED, BARE AND EXPOSED ELECTRICAL DEVICES AND WIRING IN THE FRONT ROOM, HALLWAY AND BEDROOM. TEP DID DISCONNECT POWER OFF AT THE PEDESTAL TO UNIT 1 PLUMBING: SWG STATED NO GAS TO THE DWELLING MECHANICAL: HEAVY SMOKE DAMAGE IN THE INTERIOR. REMARKS: THE DWELLING WAS CONDEMNED, PERMIT REQUIRED FOR ALL REPAIRS. OWNER SIGNED ALL DOCUMENTS. OWNER STATED HE WILL HAVE THE DAMAGED OPENINGS SECURED.
12/23/2019 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL DOCUMENTS IN SIRE. CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T19DV09502
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
12/21/2019 CONTACTED IN PERSON
12/21/2019 NOTICE AND ORDER ISSUED
12/21/2019 VIOLATION CLOSED
12/21/2019 STRUCTURE SECURED BY ???
12/21/2019 CALLBACK