Case: T19DV09474
Case Details
Entered Date:
12/19/2019
Applicant:
WARD HORTENSE 1/2 & ALVAREZ ELOISE WARD & MANUEL A & DAVY GLORIA ALL JT/RS 1/2
Description:
living conditions, no heat, and electrical issues
Outstanding Inspections
Case Number: T19DV09474
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T19DV09474
Case Description: EMERGENCY
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2019 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED THE SITE, MET WITH TPD OFFICERS. ELDERLY FATHER WAS LIVING WITH 9YR OLD SON IN THE STRUCTURE. TPD CLAIMED THAT THE STRUCTURE SEEMED UNFIT FOR THE SON TO BE LIVING AND REQUIRED A INSPECTION. MY FINDINGS ARE AS FOLLOWS: STRUCTURE: >BUILDING IS A ADOBE / PLASTER STRUCTURE. INTERIOR CEILINGS WERE DILAPIDATED THRU OUT THE STRUCTURE, IN THE BEDROOMS BUT A LARGE 4FT X 4FT HOLE IN CENTER OF THE KITCHEN AND A 3FT X 3FT HOLE IN THE N/E CORNER OF THE KITCHEN THAT EXPOSED ELECTRICAL. PLASTER WAS AT LEAST 1 INCH THICK AND WILL CONTINUE FALL FROM THE RAFTERS >APPEARS LEAKS WERE CAUSED BY LEAKING FROM THE DETERIORATED ROOF. I WOULD NOT BE WILLING TO WALK ON THE ROOF. >LEAKS CAUSED WOOD ROT AND POSSIBLE TERMITE DAMAGE THRU OUT THE STRUCTURE, IN THE CEILING RAFTERS, DOOR JAMBS, JUST ABOUT ANYTHING WOOD. >LARGE CRACKS APPEARING IN ALL ROOMS ELECTRICAL: >WIRING WAS EXPOSED IN THE CEILING FROM MISSING PLASTER >FOUND EXPOSED WIRING FROM MISSING LIGHT FIXTURE, ELECTRICAL OUTLETS AND SWITCHES NOT COMPLETED, AND MISSING COVER PLATES THRU OUT. >BARE WIRING TO A OUTLET, NO BOX RAN FROM THE KITCHEN THRU THE REAR CARPORT, TO A SHED IN THE REAR YARD. >ELECTRICAL SERVICE PANEL NOT PROPERLY WIRED, SERVICE TURNED OFF AND METER BOOTED. SERVICE RECCONECT REQUIRED. PLUMBING: STRUCTURE LACKS GAS. HOTWATER HEATER ALSO NOT WORKING. UNIT HAS NO HOT WATER. MECHANICAL: COOLER ON THE ROOF LOOKS BURNED OUT FROM THE ELECTRICAL ATTACHED TO THE SIDE OF THE COOLER, EXPOSED TO THE ELEMENTS, NOT COVERED. > HEATER NOT WORKING DUE TO LACK OF GAS. (PLUMBING ISSUE) LIVING CONDITIONS: >NO WORKING SMOKE DETECTORS >EXISTS IN ALL BEDROOMS BLOCKED MAKING EXITING THE STRUCTURE DIFFICULT. >STRUCTURE UNSANITARY AND COULD CAUSE SICKNESS FROM THE CONDITIONS. COULD USE CLEANING AND MOPPING. > SMALL AMOUNT OF FOOD IN THE REFRIGERATOR. EXTERIOR: > OVERGROWN GRASS AND WEEDS, TRASH AND DEBRIS THRU OUT THE PROPERTY. >JMV'S ON THE PROPERTY ** TEP CUT POWER TO THE STRUCTURE. ** 3 DOGS AND 2 CHICKENS REMOVED BY PIMA ANIMAL CONTROL **TPD CHECKED WELFARE OF THE MINOR WHILE AT SCHOOL AND CHECKED WITH THE NURSE. ** CPS WAS CONTACTED. **STRUCTURE WAS BOARDED AND POSTED NOV WAS ISSUED BUT OWNER LEFT UNANNOUNCED AND DID NOT SIGN NOV. |