Case: T19DV08974
Case Details
Entered Date:
11/19/2019
Applicant:
BONBON LLC
Description:
Outdoor Lighting Code. Mini-dorm installed exterior flood lights that shines directly on my property in violation of the lighting code in terms of angle, shielding, total property lumens, and hours of operation. I sent a letter to the owners on October 29, 2019 with no response.
Completed Inspections
Case Status: COMPLIAN
Case Number: T19DV08974
Case Description: LIGHTING VIOLATION
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2020 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | THE HOME HAS AN UNSHIELDED LIGHT FIXTURE ON THE NORTHSIDE OF THE DWELLING, THERE IS LIGHT TRESPASS TO THE DWELLING NEXT DOOR, |
| 05/12/2020 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | LIGHT FIXTURES HAVE BEEN ANGLED DOWNWARD AND HAVE BEEN SHIELED. IAW WITH 45 DEGREE. CLOSE CASE |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 04/08/2020 | TUCSON CODE, 2012 TUCSON/ PIMA COUNTY OUTDOOR LIGHTING CODE, SECTION 104 PERMITS AND PLAN SUBMISSION REQUIREMENTS 104.1 PERMITS REQUIRED. ANY OWNER OR AUTHORIZED AGENT WHO INTENDS TO INSTALL, CONSTRUCT, ENLARGE, ALTER, REPAIR, MOVE, OR CHANGE ANY OUTDOOR LIGHTING WITHIN PIMA COUNTY JURISDICTION, THE INSTALLATION OF WHICH IS REGULATED BY THIS CODE, SHALL FIRST MAKE APPLICATION TO THE BUILDING OFFICIAL FOR PIMA COUNTY AND OBTAIN THE REQUIRED PERMIT. 2012 TUCSON/ PIMA COUNTY OUTDOOR LIGHTING CODE 401.3 SHIELDING REQUIREMENTS. ALL LIGHT FIXTURES THAT ARE REQUIRED TO BE SHIELDED SHALL BE INSTALLED IN SUCH A MANNER THAT THE SHIELDING IS EFFECTIVE AND PERMANENT. 401.3.1 LIGHT TRESPASS. LIGHT FIXTURES ON THE RESIDENTIAL SIDE OF COMMERCIAL PROPERTY ADJACENT TO RESIDENTIAL PROPERTY SHALL BE FULL CUTOFF AND SHALL BE INSTALLED NOT HIGHER THAN 10 FEET ABOVE GRADE AT THE PROPERTY LINE AND NO HIGHER THAN A LINE RISING 20 DEGREES ABOVE THE 10 FEET UNTIL 100 FEET FROM THE PROPERTY LINE, MEASURED PERPENDICULAR TO THE LOT LINE. 401.3.2 HOUSE SIDE SHIELDS. OUTDOOR LIGHTING FIXTURES CLOSER TO THE LOT LINE THAN THE MOUNTING HEIGHT OF THE FIXTURE, MEASURED PERPENDICULAR TO THE LOT LINE, ADJACENT TO RESIDENTIAL AREAS, SHALL HAVE INTERNAL HOUSE-SIDE SHIELDS. 401.3.4 FLOOD AND SPOT LAMPS. FLOOD OR SPOT LAMPS SHALL BE AIMED NO HIGHER THAN 45 DEGREES TO THE HORIZONTAL (HALF-WAY BETWEEN STRAIGHT DOWN AND STRAIGHT TO THE SIDE) WHEN THE SOURCE IS VISIBLE FROM ANY ADJACENT RESIDENTIAL PROPERTY. | Not Approved |
Completed Activity Special Conditions
Case Description - LIGHTING VIOLATION
Case Number - T19DV08974
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 05/07/2020 | CONTACTED BY PHONE |
| 04/08/2020 | CONTACTED BY EMAIL |
| 04/10/2020 | NOTICE OF VIOLATION ISSUED |
| 05/12/2020 | VIOLATION CLOSED |