Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EXCESSIVE INTERIOR STORAGE
Address:

Entered Date:

09/26/2019

Applicant:

WILKINSON BRAD L & KAROLAN CP/RS

Description:

TPD - EMERGENCY CALL OUT - HOARDER SITUATION OFFICER ON SITE

Case Violations

Case Number: T19DV07534
Case Status: COMPLIAN
Case Description: EXCESSIVE INTERIOR STORAGE
Total Violations: 2
Violation Date Code Statue
09/26/2019 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (3) Every habitable room must have at least two electrical receptacle outlets, or one outlet and one electric light fixture. Every bathroom, water closet compartment, and laundry room must have at least one electric light fixture.
09/26/2019 T.C. Ch. 16, Sec. 16-11(a)(2) Every dwelling unit or guest room shall have unobstructed access directly to the outside, or to a public corridor. Every door, stairway, passageway or other means of exit shall be of sufficient size, width and arrangement so as to provide safe and rapid egress in the event of fire. Every walking surface of any means of exit shall be maintained free of warping, rotting, or other damage or obstructions so as to provide safe and rapid egress in the event of fire.

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV07534
Case Description: EXCESSIVE INTERIOR STORAGE
Total Completed Inspections - 3
End Date Description Inspector Results Comments
09/26/2019 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Was called to check a built up beam on a 12' span was OK to remain with out supports. The beam was a 4 x 12 solid with rough 2 x 12's bolted to both sides of the other beam. The beam has been in place for some time and was all exposed in the area. Has a leadger for another roof attached to the rear room that has been added and again for some time. The beam has no sag at this time. The beam is OK to remain on site with out supports. RV.
09/26/2019 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TPD: TPD CONCERNS WERE THE INTERIOR LIVING CONDITIONS. THE INSPECTION RESULTS/; HALF OF THE LIVING HAS BEEN PARTITIONED INTO A BEDROOM. THERE ARE LOCKING HASPS ON THE BEDROOMS DOOR AND THE EXIT DOORS. THERE ARE OPENINGS IN THE ELECTRICAL ENCLOSURES WITH EXPOSED WIRING. A NOTICE OF VIOLATION WILL BE ISSUED AND OCCUPANCY CONTINUES
10/17/2019 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ABATED CLOSE CASE

Outstanding Case Activity Conditions

Date Name Approved
10/01/2019 2018 INTERNATIONAL RESIDENTIAL CODE CHAPTER 3 BUILDING PLANNING SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS R310.1.1 OPERATIONAL CONSTRAINTS AND OPENING CONTROL DEVICES. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. WINDOW OPENING CONTROL DEVICES ON WINDOWS SERVING AS A REQUIRED EMERGENCY ESCAPE AND RESCUE OPENING SHALL COMPLY WITH ASTM F2090. Not Approved

Completed Activity Special Conditions

Case Description - EXCESSIVE INTERIOR STORAGE
Case Number - T19DV07534
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
09/26/2019 CONTACTED IN PERSON
10/17/2019 VIOLATION CLOSED