Case: T19DV07534
Case Details
Entered Date:
09/26/2019
Applicant:
WILKINSON BRAD L & KAROLAN CP/RS
Description:
TPD - EMERGENCY CALL OUT - HOARDER SITUATION OFFICER ON SITE
Case Violations
Case Number: T19DV07534
Case Status: COMPLIAN
Case Description: EXCESSIVE INTERIOR STORAGE
Total Violations: 2
Violation Date | Code Statue |
---|---|
09/26/2019 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (3) Every habitable room must have at least two electrical receptacle outlets, or one outlet and one electric light fixture. Every bathroom, water closet compartment, and laundry room must have at least one electric light fixture. |
09/26/2019 | T.C. Ch. 16, Sec. 16-11(a)(2) Every dwelling unit or guest room shall have unobstructed access directly to the outside, or to a public corridor. Every door, stairway, passageway or other means of exit shall be of sufficient size, width and arrangement so as to provide safe and rapid egress in the event of fire. Every walking surface of any means of exit shall be maintained free of warping, rotting, or other damage or obstructions so as to provide safe and rapid egress in the event of fire. |
Completed Inspections
Case Status: COMPLIAN
Case Number: T19DV07534
Case Description: EXCESSIVE INTERIOR STORAGE
Total Completed Inspections - 3
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2019 | INSP - INITIAL CODE ENFORCMENT | VIDAL | Approved | Was called to check a built up beam on a 12' span was OK to remain with out supports. The beam was a 4 x 12 solid with rough 2 x 12's bolted to both sides of the other beam. The beam has been in place for some time and was all exposed in the area. Has a leadger for another roof attached to the rear room that has been added and again for some time. The beam has no sag at this time. The beam is OK to remain on site with out supports. RV. |
09/26/2019 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | EMERGENCY CALL OUT BY TPD: TPD CONCERNS WERE THE INTERIOR LIVING CONDITIONS. THE INSPECTION RESULTS/; HALF OF THE LIVING HAS BEEN PARTITIONED INTO A BEDROOM. THERE ARE LOCKING HASPS ON THE BEDROOMS DOOR AND THE EXIT DOORS. THERE ARE OPENINGS IN THE ELECTRICAL ENCLOSURES WITH EXPOSED WIRING. A NOTICE OF VIOLATION WILL BE ISSUED AND OCCUPANCY CONTINUES |
10/17/2019 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ABATED CLOSE CASE |
Outstanding Case Activity Conditions
Date | Name | Approved |
10/01/2019 | 2018 INTERNATIONAL RESIDENTIAL CODE CHAPTER 3 BUILDING PLANNING SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS R310.1.1 OPERATIONAL CONSTRAINTS AND OPENING CONTROL DEVICES. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. WINDOW OPENING CONTROL DEVICES ON WINDOWS SERVING AS A REQUIRED EMERGENCY ESCAPE AND RESCUE OPENING SHALL COMPLY WITH ASTM F2090. | Not Approved |
Completed Activity Special Conditions
Case Description - EXCESSIVE INTERIOR STORAGE
Case Number - T19DV07534
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date | Name |
09/26/2019 | CONTACTED IN PERSON |
10/17/2019 | VIOLATION CLOSED |