Case: T19DV06252
Case Details
Entered Date:
08/05/2019
Applicant:
N/A
Description:
Case Violations
Case Number: T19DV06252
Case Status: Closed - Resolved
Case Description: #9 RWOP remodeling trailer
Total Violations: 4
| Violation Date | Code Statue |
|---|---|
| 08/09/2019 | T.C. Ch. 16, Sec. 16-4 PERMITS REQUIRED Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. (Ord. No. 9816, ยง 15, 2-24-03) Sec. 16-45(3)(a). Notice of violation. If the action required is a repair, the notice shall direct that all required permits be secured for the repair, and that the repair work shall be commenced and completed within such time, not to exceed sixty (60) days, as the code official determines is reasonable under the circumstances |
| 08/09/2019 | UDC Sec. 10.2.3 COMPLIANCE REVIEW, EXISTING DEVELOPMENT Any land used or occupied; any site improvement, modification, or construction started; any existing use or structure expanded, reconstructed, changed, or otherwise altered; and any land divided into multiple parcels without certification of compliance with the provisions of the UDC through a zoning review process is considered a violation of the UDC. Enforcement of violations shall be in accordance with Section 10.4, Penalties and Remedies. |
| 08/09/2019 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. |
| 08/09/2019 | T.C. Ch. 16, Sec. 16-11(c)(1) ELECTRICAL SYSTEM All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. |
Completed Inspections
Case Status: Closed - Resolved
Case Number: T19DV06252
Case Description: #9 RWOP remodeling trailer
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2019 | COT - ENFC - Code Enforcement - Initial | Passed | {Activity date: 08/05/2019; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - PARCEL: 107-14-1750 ADDRESS: 2525 N. CASTRO AVE MULTIPLE ELECTRICAL HAZARDS WERE IDENTIFIED ON 8/6/2019, ENERGIZED OVER HEAD FEEDERS ARE UNSTABLE AND DILAPIDATED. POWER WAS TERMINATED BY THE OWNER'S ELECTRICAL CONTRACTOR AND SECURED A DAMAGED POST WITH A TEMPORARY, ON SITE REPAIR. ENGINEERING AND PERMITS WILL BE REQUIRED TO WORK ON THE PARK'S INFRASTRUCTURE TO THE R-3 ZONED PROPERTY. VACANT SPACES ARE AS FOLLOWED: 15, 16, 17, 18, 21, 22, 35, and 36 (BASED ON MY BEST JUDGMENT MOBILE UNITS DO NOT COINCIDE WITH MARK UNITS) THERE ARE OTHER VACANT SPACES WITHOUT ANY TYPE OF INDICATION, WILL PROVIDE AERIAL WITH MARKED VACANT SPACES) RV'S ARE NOT AN APPROVED USE IN AN R3 ZONE, PROPERTY MUST HAVE A ZONING SITE PLAN APPROVED FOR THE MIX USE OF R.V.S, MOBILE HOMES AND THE DUPLEXES ON THE PROPERTY. MULTIPLE OVERHEAD FEEDER'S POST AND PEDESTALS ARE EITHER UNSTABLE, DILAPIDATED OR HAVE COLLAPSED THEY ARE IN NEED OF REPAIR OR REPLACEMENT. OVER HEAD FEEDERS ARE TANGLED, NOT PROPERLY ANCHORED THE ABUTTING POST. FEEDERS ARE WITHIN 8 FEET OF THE DWELLING ROOF TOPS. NON PERMITTED OUTDOOR LIGHTING ARE DIRECTLY CONNECTED TO THE OVERHEAD FEEDERS WITHOUT OVER CURRENT PROTECTION. MAIN SERVICE PANEL, DOWNSTREAM PANELS AND PEDESTALS ARE LACK GROUNDING OR GROUNDING NEEDS TO BE VERIFY IF MODIFICATIONS ARE CODE COMPLIANT AND MEET MANUFACTURES REQUIREMENTS. MAIN DISCONNECT AND DOWNSTREAM PANELS LACK OF PROPER LABELING/DIRECTORY. DOWNSTREAM PANELS AND PEDESTALS HAVE UNUSED OPENINGS, MODIFICATIONS AND OR MISSING DEAD FRONTS. THERE IS UNPROTECTED AND OR DAMAGED CONDUCTORS, CONDUIT THAT ARE EXPOSED TO THE ELEMENTS. THERE ARE MULTIPLE CIRCUIT BREAKERS MIXED WITH NON COMPATIBLE EQUIPMENT AND OR UN-READABLE. THERE ARE MAIN SERVICE EQUIPMENT BEING USED IN A NON CODE COMPLAINT METHOD AGAINST MANUFACTURES LISTING. UNIT NUMBER 20-1 AND 20-2: WOOD MEMBER FOUNDATION IS DILAPIDATED CURRENTLY BEING SUPPORTED BY CLAY PIPING AND SHOWING SIGNS OF WOOD ROT AND DECAY. THE UNIT'S INTERIOR LACK OF FIRE SAFETY EQUIPMENT. EGRESS HAS BEEN RESTRICTED WITH WINDOW MOUNT AC UNITS OR BOARDING. OCCUPANTS ARE USING ALTERNATIVE POWER VIA BATTERIES AND ABUSING THE USE OF EXTENSION CORDS FOR SUPPLEMENTAL POWER FOR INTERNAL USE. INTERIOR ELECTRICAL HAS BEEN MODIFIED TO A NON CODE COMPLAINT METHODS. THE DWELLINGS LACKS OF AN APPROVED FURNACE OR HEATING APPLIANCE CAUSING THE OCCUPANTS TO USE THE STOVE AS AN ALTERNATIVE. UNIT NUMBER 19-1 AND 19-2: PLUMBING IS NOT PROPERLY CONNECTED OR IS DAMAGED CAUSING A SEWER LEAK UNDERNEATH THE WOOD FLOOR RAFTERS TO BOTH UNITS. THE UNIT'S INTERIOR LACKS OF FIRE SAFETY EQUIPMENT. EGRESS HAS BEEN RESTRICTED FROM THE MODIFIED FLOOR PLAN, AND UNIT'S APPLIANCES. INTERIOR ELECTRICAL HAS BEEN MODIFIED TO A NON CODE COMPLAINT METHOD. UNSTABLE FLOORING IN THE BATHROOM HAS SIGNS OF DETERIORATION AND SHIFTING. THE NEWLY INSTALLED ELECTRIC WATER HEATER WITH MANUFACTURE LABEL OF 2018 HAS BEEN INSTALLED WITHOUT A PERMIT BLOCKING THE DWELLING'S WINDOW. } | |
| 08/03/2020 | COT - ENFC - Code Enforcement - Follow Up | Passed | {Activity date: 08/03/2020; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - Civil Infraction Submittal Aug 03, 2020 11:36 AM LONG FORM HAS BEEN SUBMITTED TO CITY PROSECUTOR'S OFFICE.} ; {Activity date: 06/22/2020; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - LITTLE TO NO CHANGE ON THE PROPERTY} ; {Activity date: 07/30/2020; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - AFTER GENEROUS AMOUNT OF EXTENSIONS AND CONSIDERATION, RESPONSIBLE PARTY HAS FAILED TO OBTAIN PERMITS AND MAKE PROPER PERMANENT REPAIRS TO THE ELECTRICAL ENERGIZING THE MOBILE HOME PARK. UNIT 11 AND 12 REMAINS IN AN UNINHABITABLE STATE, THIS PROPERTY HAS HISTORY OF NEGLECT. CASE WILL BE SUBMITTED TO THE CITY PROSECUTOR'S OFFICE TO SUMMONS RESPONSIBLE PARTY FOR NON-COMPLIANCE.} ; {Activity date: 05/04/2020; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - LITTLE TO NO CHANGE ON THE PROPERTY.} ; {Activity date: 02/20/2020; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - PERMIT T20CM01009 IS PENDING TO BE APPROVED BY THE CITY FOR A 600 AMP ELECTRICAL SERVICE.} ; {Activity date: 10/08/2019; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - UNITS 19-1, 19-2, 20-1, 20-2 HAS BEEN DEMOLISHED WITH PROPER CITY PERMITS. ALL TRASH AND DEBRIS HAS BEEN DISPOSED. PENDING ELECTRICAL VIOLATIONS, AN APPROVED SITE PLAN, AND PROPER ADDRESSING OF SPACE NUMBERS.} |
Completed Case Activity
Case Number - T19DV06252
Case Status: Closed - Resolved
Case Description: #9 RWOP remodeling trailer
| Description | Date | Status |
| CASE IS AT PROSECUTORS OFFICE | 08/03/2020 | Passed |
| LONG FORM CITATION | 08/03/2020 | Passed |
| RESEARCH | 08/08/2019 | Passed |
| Other Activity | 08/09/2019 | Passed |
| CONTACTED BY MAILING | 08/12/2019 | Passed |
| CONTACTED BY PHONE | 08/18/2020 | Passed |
| CONTACTED BY EMAIL | 09/08/2020 | Passed |
| COURT HEARING INFO | 12/08/2020 | Passed |