Case: T19DV06037
Case Details
Entered Date:
07/25/2019
Applicant:
JOINT VENTURE EQUITIES LLC
Description:
FIRE ON THE PROPERTY
Completed Inspections
Case Status: REFERRED
Case Number: T19DV06037
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2019 | INSP - INITIAL CODE ENFORCMENT | GONZALEZ | Approved | 203 W SAHUARO AND 214 W SAHUARO ARE SIDE BY SIDE ADDRESSES ON THE SAME SIDE OF THE STREET (POSSIBLE ERROR THAT NEEDS CORRECTION) CONTENT FIRE OCCURRED IN UNIT 3, UNIT 3 IS A VACANT AND UNSECURED STRUCTURE. THIS UNIT HAS BEEN GUTTED OUT PREVIOUS FROM THE FIRE. UNPERMITTED WORK HAS OCCURRED TO THE PLUMBING, STRUCTURE AND ELECTRICAL. ONE MASTER ELECTRIC METER THAT PROVIDES ELECTRIC TO 203 W SAGUARO AND 214 W SAGUARO, HAS HAD A SERVICE UPGRADE WITHOUT PERMITS OR APPROVALS WITH UNPERMITTED WIRING DATE STAMPED OF 11/23/2013 THESE SAME WIRES WITH DATE STAMP CAN BE FOUND AT ALL THE STRUCTURES AT THESE ADDRESSES. T.E.P FOUND THE RING AROUND THE ELECTRIC METER HAS BEEN TAMPERED, AND THE CONNECTIONS TO THE SERVICE DROP AND TO THE WEATHER HEAD WAS NOT CONNECTED BY A T.E.P. TECH DUE TO MISSING HARDWARE USED BY THE UTILITY. T.E.P DISCONNECTED POWER FROM THE POLE AND PLACED A CLEARANCE FOR A PERMIT TO BE OBTAIN BEFORE ENERGIZED. SOUTH WEST GAS TURNED AND LOCKED THEIR UTILITY METER DUE TO UNPERMITTED AND NON CODE COMPLAINT MODIFICATIONS TO BOTH ADDRESS. EXISTING STRUCTURES HAS NON CODE COMPLIANT ADDITIONS LACKING A FOUNDATION, PROPER INTERIOR ROOF HEIGHT AND UNDER SIZED EGRESS WINDOW OPENINGS. THE DWELLINGS LACKS OF SMOKE DETECTORS, ROOF HAVE WATER PENETRATIONS AND DRYWALL DAMAGE FROM MOISTURE. BEDROOMS DO NO HAVE STORAGE CLOSETS, CAUSING OCCUPANTS TO STORE PERSONAL ITEMS IN AND AROUND THE GAS OPERATED FURNACE THAT HAS BEEN INSTALLED IN A NON CODE COMPLIANT MANNER, THIS FURNACE HAS 2015 LABELING. HVAC UNITS HAVE BEEN INSTALLED TO THE UNITS ROOF TOP AND HAS NON CODE COMPLAINT WIRING METHODS. GAS STOVE ARE MISSING MECHANICAL HOODS, THERE ARE MULTIPLE PEX PLUMBING THROUGH OUT THE PROPERTY THAT HAVE BEEN INSTALLED AND NOT PROPERLY ANCHORED OR SUPPORTED. PROPERTY HAS BEEN POSTED UNFIT TO OCCUPY WITH NOTICE AND ORDER. TENANTS MADE CONTACT WITH THE RED CROSS AND ARE AWARE OF CONDEMNATION. OCCUPANTS AND THE NEW PROPERTY OWNER ARE AWARE TO KEEP THE UNITS VACANT AND SECURED. PROPERTY OWNER IS AWARE THAT PERMITS ARE REQUIRED FOR THE CONSTRUCTION AND MODIFICATIONS ON THE PROPERTY. OWNER HAS BEEN INFORMED THAT PERMITS ARE ONLY REQUIRED TO DEMO STRUCTURES THAT HAVE BEEN PERMITTED ON THE PROPERTY. |
| 07/26/2019 | INSP - FOLLOW UP CODE ENFORCE | GONZALEZ | Approved | REFERENCE CASE NUMBER T19DV06060 FOR MORE INFORMATION |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T19DV06037
Case Status: REFERRED
Total Completed Case Activity Conditions: 1
| Date | Name |
| 07/26/2019 | VIOLATION CLOSED |