Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-RESIDENTL

Entered Date:

06/25/2019

Applicant:

DANIEL R HERBISON & PAMELA WETHERINGTON CP/RS

Description:

Bright lights and build metal structure attached to the common wall - 30 ft long/10 ft wide/6 ft tall (No action from HOA AMDIN- Sue Guidraitis)

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV05127
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/17/2019 INSP - INITIAL CODE ENFORCMENT LOPEZ Approved AFTER INSPECTION FOUND THAT STRUCTURE NOT PERMANENT AND HAS NETTING TARP FOR SHADE AND MADE OF SQ. TUBING NOT A SOLID STRUCTURE, NO PERMIT NEEEDED. BUT WILL ISSUE NOTICE FOR LIGHTS NOT AT A 45 DEGREE ANGEL AND NOt SHEILDED.
08/13/2019 INSP - FOLLOW UP CODE ENFORCE LOPEZ Approved VIOLATION ABATED, HAS PLACE SMALL LIGHTS WITH SHEILDS AND AT A 45 DEGREES. CLOSING CASE

Outstanding Case Activity Conditions

Date Name Approved
07/18/2019 2012 TUCSON/ PIMA COUNTY OUTDOOR LIGHTING CODE 401.3 SHIELDING REQUIREMENTS. ALL LIGHT FIXTURES THAT ARE REQUIRED TO BE SHIELDED SHALL BE INSTALLED IN SUCH A MANNER THAT THE SHIELDING IS EFFECTIVE AND PERMANENT. 401.3.1 LIGHT TRESPASS. LIGHT FIXTURES ON THE RESIDENTIAL SIDE OF COMMERCIAL PROPERTY ADJACENT TO RESIDENTIAL PROPERTY SHALL BE FULL CUTOFF AND SHALL BE INSTALLED NOT HIGHER THAN 10 FEET ABOVE GRADE AT THE PROPERTY LINE AND NO HIGHER THAN A LINE RISING 20 DEGREES ABOVE THE 10 FEET UNTIL 100 FEET FROM THE PROPERTY LINE, MEASURED PERPENDICULAR TO THE LOT LINE. 401.3.2 HOUSE SIDE SHIELDS. OUTDOOR LIGHTING FIXTURES CLOSER TO THE LOT LINE THAN THE MOUNTING HEIGHT OF THE FIXTURE, MEASURED PERPENDICULAR TO THE LOT LINE, ADJACENT TO RESIDENTIAL AREAS, SHALL HAVE INTERNAL HOUSE-SIDE SHIELDS. 401.3.3 FIXTURES WITHIN 25 FEET OF RESIDENTIAL LOT LINES. RESIDENTIAL AND COMMERCIAL LUMINAIRES SHALL BE FULL CUTOFF WITHIN 25 FEET OF ADJACENT RESIDENTIAL PROPERTY LINES, MEASURED PERPENDICULAR TO THE LOT LINE. 401.3.4 FLOOD AND SPOT LAMPS. FLOOD OR SPOT LAMPS SHALL BE AIMED NO HIGHER THAN 45 DEGREES TO THE HORIZONTAL (HALF-WAY BETWEEN STRAIGHT DOWN AND STRAIGHT TO THE SIDE) WHEN THE SOURCE IS VISIBLE FROM ANY ADJACENT RESIDENTIAL PROPERTY. Not Approved

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T19DV05127
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
07/17/2019 CONTACTED BY MAILING
07/17/2019 NOTICE OF VIOLATION ISSUED