Case: T19DV04122
Case Details
Entered Date:
05/18/2019
Applicant:
WILSON DORIS & LOWENTHAL SHERRY JT/RS
Description:
FIRE TO DETCHED LAUNDRY ROOM AND GARAGE
Completed Inspections
Case Status: COMPLIAN
Case Number: T19DV04122
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/18/2019 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | EMERGENCY CALL OUT BY TFD: THE DETACHED WOOD FRAMED LAUNDRY WAS COMPLETELY DESTROYED BY THE FIRE THIS ROOM WAS ADJACENT TO THE GARAGE WHICH IS A BLOCK BUILDING. THE GARAGE SUSTAIN FIRE DAMAGE TO OVER 20 FEET OF EAVE AREA TO INCLUDE ALL THE TRUSS TAILS ON THE EASTSIDE OF THE BUILDING, THE FRONT EAVE AREA ALSO SUSTAINED FIRE DAMAGE, THIS AREA IS ESTIMATE AT 16 FEET TO INCLUDE THE RIDGE BOARD. THE EAVE AREA REAR OF THE GARAGE WAS ALSO DAMAGED BY FIRE. THE GARAGE'S INTERIOR PANEL HAS MAJOR DAMAGE MELTED. THE UNDERGROUND FEED'S RISER WHICH ENTERS THE GARAGE IS ALSO MELTED. THE MAIN DISCONNECT HAS HAZARDOUS WIRING METHODS, NO DEAD FRONT / COVER. THERE IS A PENETRATION IN THE MAIN DISCONNECT WITH MULTIPLE WIRES WHICH COME FROM THE INTERIOR DRAPED OVER THE CIRCUIT BREAKER, THERE ARE UNREADABLE CIRCUIT BREAKERS, THERE ARE UNSEATED CIRCUIT BREAKERS, BRANCH CIRCUITS NOT PROTECTED. THERE IS A BATTERY PACK DIRECTLY IN FRONT OF THE DISCONNECT WITH UN PROTECT WIRING ENTERING THE BUILDING. OWNER STATED THE BATTERY PACK IS FOR HIS SOLAR SYSTEM. THE BATTERY PACK IS ALSO NOT PROTECTED. THIS DISCONNECT IS ATTACHED TO ANOTHER DETACHED BUILDING / TOOL ROOM. ON THE WESTSIDE OF THE DWELLING. THE INTERIOR OF THIS TOOL ROOM HAS MULTIPLE J BOXES WITH MISSING COVER PLATES EXPOSED WIRING / NOT PROTECTED. THE UNAPPROVED WIRING METHODS CONTINUE TO THE MULTIPLE LIGHT FIXTURES AND DEVICES. POWER WAS ORDERED TO BE DISCONNECTED DUE TO THE HAZARDOUS WIRING AND MULTIPLE CODE VIOLATIONS. PERMITS IS REQUIRED FOR THE REPAIRS TO THE GARAGE ROOF ASSEMBLY AND ELECTRICAL. PERMIT REQUIRED FOR THE ELECTRICAL REPAIRS TO THE MAIN DISCONNECT AND ALL ACCESSORY BUILDINGS A DETAILED PLAN WILL BE REQUIRED. RESTRICTIONS ARE AS FOLLOWS: DAY TIME ACCESS ONLY FOR REPAIRS AND CLEAN UP. POSTED THE UNFIT TO OCCUPY PLACARD |
| 05/21/2019 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ALL DOCUMENTS AND PHOTOS IN SIRE CLOSE CASE |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T19DV04122
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 05/18/2019 | CONTACTED IN PERSON |
| 05/18/2019 | NOTICE AND ORDER ISSUED |
| 05/21/2019 | VIOLATION CLOSED |
| 05/18/2019 | STRUCTURE SECURED BY ??? |
| 05/18/2019 | CALLBACK |