Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

05/01/2019

Applicant:

CLAUDIA NISCHWITZ

Description:

sewage backup in the baTHROOM, STRUCTURAL CRACKS IN WALLS, FOUNDATION OIS UNSTABLE

Case Violations

Case Number: T19DV03550
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
05/13/2019 REFERENCE
05/13/2019 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
05/13/2019 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
05/13/2019 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
05/13/2019 T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (7) Any portion of a building or structure that has wracked, warped, buckled or settled to such an extent that walls or other structural portions have materially less resistance to winds or earthquakes than is required in the case of similar new construction.

Outstanding Inspections

Case Number: T19DV03550
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
NPO(PL)-PLUMBING SYSTEM & FX None Not Inspected
NPO - EXT. BUILDING MAINTENANC None Not Inspected
NPO - WORK WITHOUT PERMIT None Not Inspected
NPO - INT. BUILDING MAINTENANC None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV03550
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
05/13/2019 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved STRUCTUAL CRACKING NEAR FRONT DOOR, BOTH EXTERIOR AND INTERIOR WALLS. CRACKING EXTENDS TO SAME AREA OF THE STRUCTURE IN THE SOUTH EAST BEDROOM AND MAIN BATHROOM PLUMBING IN THE ADDITION ON THE NORTHWEST PORTION OF THE PROPERTY BACKS UP IN THE SHOWER WHEN THE WASHER IS USED FRONT AND SIDE DOORS DO NOT SEAL PROPERLY SMOKE DETECTOR INSTALLED IN THE KITCHEN. SHOULD BE RELOCATED TO THE LIVING ROOM AREA NEAR THE HALL ELECTRICAL WATER HEATER INSTALLED APPROX 2016 TO 2018 ON THE WEST SIDE OF THE PROPERTY WITHOUT PERMIT LARGE A/C/HEATER SYSTEM INSTALLED APPROX 2016 TO 2018 ON THE ROOF WITHOUT PERMIT/TRUSS CALCULATIONS REAR BEDROOM/BATHROOM ADDITION BUILT PRIOR 1998. WILL RESEARCH TO DETERMINE IF PERMITTED.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T19DV03550
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
10/08/2019 CONTACTED BY PHONE
05/13/2019 CONTACTED BY MAILING
05/13/2019 NOTICE OF VIOLATION ISSUED
11/20/2019 VIOLATION CLOSED
05/13/2019 RESEARCH