Case: T19DV03178
Case Details
Entered Date:
04/23/2019
Applicant:
MENSCHING CYNTHIA R
Description:
HOUSE FIRE
Outstanding Inspections
Case Number: T19DV03178
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T19DV03178
Case Description: EMERGENCY
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/23/2019 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED SITE, MET WITH TFD INVESTIGATORS, FIRE STARTED IN THE CARPORT AREA, SPREAD INTO THE LIVINGROOM AS THERE WAS NO FIRE STOP BETWEEN THE GARAGE AND THE MAIN STRUCTURE. CAUSE OF THE FIRE HAD NOT YET BEEN DETERMINED, MY FINDINGS ARE AS FOLLOWS: STRUCTURAL >THE SOUTH BEARING WALL OF THE GARAGE RECEIVED HEAVY FIRE DAMAGE, STUDS, DBL TOP PLATE AND SIDING WERE ALL FIRE DAMAGED, AS WELL AS THE METAL ROOF (COVERING). >ALL FIRE RATED DRYWALL, CEILING AND WALLS WAS BURNED AND REMOVED FROM THE CEILING. > A PORTION OF THE WASHER/DRYER ROOM WAS FIRE DAMAGED, STUDS AND SIDING BURNED AND HEAVY SMOKE DAMAGE ON THE INTERIOR. >THE TRUSSES IN THE LIVING ROOM WERE ALSO FIRE DAMAGED AS WELL AS THE ROOF SHEATHING. DRWALL WAS PARTIALLY REMOVED FROM THE CEILING. ELECTRICAL >ALL ELECTRICAL WIRING, OUTLETS, AND SWITCHES WERE FIRE DAMAGED IN THE GARAGE AREA. >WIRING FOR THE A/C ALSO RAN ON TOP OF THE GARAGE ROOF, WIRING GOING INTO THE WASHER/ DRYER ROOM WAS FIRE DAMAGED AND WIRING IN THE LIVING ROOM AREA ALSO FIRE DAMAGED AND/LEFT EXPOSED. > SERVICE PANEL WAS NOT WELL MARKED. METER WAS BOOTED BY TEP AND ELECTRICAL RECONNECT WILL BE REQUIRED. MECHANICAL >WIRING TO THE HEAT PACK UNIT AND GAS LINE TO THE FURNACE MAY NEED TO BE REPLACED. PLUMBING >HOT WATER HEATER MAY NEED TO BE REPLACED AS IT WAS OFF THE HALLWAY NEXT TO THE LIVINGROOM AREA. WATER WAS LEFT ON. EMERGENCY VACATE NOV WAS ISSUED AND PERMITS REQUIRED INCLUDED ON THE NOV. NOV WAS SIGNED FOR BY THE OWNER CYNTHIA MENSHING. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T19DV03178
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 04/24/2019 | NOTICE OF VIOLATION ISSUED |
| 04/25/2019 | VIOLATION CLOSED |
| 03/17/2022 | SEC LEIN PLACED ON PROPERTY IN THE AMOUNT OF ??? |
| 06/10/2019 | SEC LETTER OF BILLING FOR $??? SENT TO OWNERS |