Case: T19DV01629
Case Details
Entered Date:
03/08/2019
Applicant:
CHRISTOPHER DRISCOLL
Description:
HOUSE FIRE / WWO PERMITS
Completed Inspections
Case Status: COMPLIAN
Case Number: T19DV01629
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/08/2019 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | EMERGENCY CALL OUT BY TFD THIS PROPERTY HAS TWO DWELLINGS AND 2 SMALL ACCESSORY BUILDINGS, WHILE TFD WAS WORKING ON THE CENTER DWELLING, I DID INSPECT THE FRONT DWELLING WITH THE DOOR OPENED. THIS DWELLING HAS HAD THE KITCHEN DEMOLISHED AND INTERIOR WALLS REMOVED, THE BATHROOM WAS GUTTED THE CEILING JOIST AND STUD HAVE SEVERE TERMITE DAMAGE, THERE IS A 2 INCH NEW DRAIN WASTE PIPE INSTALLED. THERE IS NO ACTIVE PERMIT FOR THIS WORK. THE METER WAS PULLED AND THE SERVICE DROP WILL BE CUT AT THE POLE IN THE MORNING. WILL SECURE THIS DWELLING AND POSTED CONDEMNATION PLACARD. THE CENTER DWELLING HAS MAJOR DAMAGE TO THE ROOF ASSEMBLY, THE REAR ROOM AND THE KITCHEN ROOF MEMBERS HAVE DEEP CRACKS AND ARE CHARRED, THE REAR ROOM CEILING JOISTS HAVE COLLAPSED, WITH A ROOF HOLE ALSO DAMAGE TO THE WINDOW OPENING AND EXTERIOR WALL. THE KITCHEN ALSO HAS ROOF MEMBERS WITH DEEP CRACKS TO INCLUDE THE CEILING JOISTS, THE SMALL HALLWAY IS IN THE SAME STATE. THE ABOVE AREAS HAVE NO CEILING OR WALL FINISH. THE DINING ROOM HAS ROOF MEMBERS WITH DEEP CRACKS THERE IS DAMAGE TO THE CEILING DRYWALL AND PLASTERED WALLS. THERE IS BURNT AND BARE WIRING WITH DAMAGED DEVICES IN THE ABOVE AREAS. THE ROOM IN THIS DWELLING HAVE INSPECTION HOLES IN THE CEILING AND MULTIPLE BROKEN WINDOWS AND UNSECURED DOORS THE FRONT BEDROOM'S BATHROOM HAS NEW FRAMING STUDS, NEW SHOWER PAN WITH NEW ABS ON THE EXTERIOR, THERE IS NEW JUNCTION BOXES. THE BEDROOM HAS NEW COIL OF PEX PIPING AND SEWER PIPE. THE EXTERIOR AREA HAS A NEW 4 INCH PIPE RUN ABOUT 20 FEET LONG WITH MULTIPLE TRENCHES IN THE FRONT OF THIS DWELLING. THE WEST SIDE REAR BUILDING HAS TWO DISCONNECTS WITH 5 NEW EMT CONDUCT RUNS GOING INTO THE CENTER DWELLING, BOTH METERS WERE PULLED AND THE SERVICE DROP WILL BE CUT AT THE POLE IN THE MORNING. THIS BUILDING HAS DAMAGE TO TWO WINDOW OPENING, THIS BUILDING APPEARS TO BE VACANT. THE EASTSIDE REAR BUILDING HAS PERSONAL ITEM INSIDE CLOTHING AND MICS ITEMS. THIS BUILDING HAS NO ROOF ASSEMBLY BUT HAS TWO DOORS AND A WINDOW OPENING THAT WILL BE SECURED. ALL BUILDINGS ON THIS PROPERTY ARE CONDEMNED, PERMITS REQUIRED FOR REPAIRS. ALL BUILDINGS WERE SECURED TO PREVENT ENTRY AND ALSO POSTED NOTICE AND ORDER WITH UNFIT TO OCCUPY PLACARD. |
| 03/12/2019 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ALL DOCUMENT SAND PHOTOS IN SIRE. CLOSE CASE |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T19DV01629
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 8
| Date | Name |
| 03/12/2019 | CONTACTED BY PHONE |
| 03/08/2019 | CONTACTED IN PERSON |
| 03/12/2019 | CONTACTED BY MAILING |
| 03/12/2019 | CONTACTED BY EMAIL |
| 03/08/2019 | NOTICE AND ORDER ISSUED |
| 04/04/2019 | SEC LETTER OF BILLING FOR $??? SENT TO OWNERS |
| 03/08/2019 | STRUCTURE SECURED BY ??? |
| 03/08/2019 | CALLBACK |