Case: T19DV01395
Case Details
Entered Date:
03/01/2019
Applicant:
GRAHAM JOSEPH W TR
Description:
unsafe structure building three in back structure is coming apart
Completed Inspections
Case Status: COMPLIAN
Case Number: T19DV01395
Case Description: DILAPIDATED STRUCTURE
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/08/2019 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | INSPECTION FOUND 2ND STORY WALKWAY DELAPIDATED AND SEPERATING FROM THE MAIN STRUCTURE. OWNERS HAVE THE 8 FT SECTION SEPERATING SHORED WITH 4X4 POSTS AND 2 X2 SHEET OF 5/8" PLYWOOD ON THE TOP. THE AREA HAS BEEN TAPED OFF WITH CAUTION TAPE' MANAGER MELLISSA STATED OWNER WAS IN OVER THE WEEKEND AND AND OK'ED MOVING FORWARD WITH THE REPAIRS. NOV WAS ISSUED TO REPAIR OR REPLACE THE WALKWAY UNDER PERMIT. |
| 04/17/2020 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | REVISITED STHE SITE, FOUND STAIRWELL REMAINED IN PLACE AND EVERY THINS HAD BEE PULLED BACK TO THE BEAM AND STAIRWELL. THE PLYWOOD WAS REMOVED AND FLOOR LEDGER REBOLTED USING A 5/8" BOLT INSTEAD OF A 1/2" BOLT PULLING THE LEDGER TO THE STRUCTURE. ALL THREE 4 X 4 POSTS WERE REPLACED, REUSING THE POST BASE AND POST CAP, THE BEAM WAS PULLED BACK TO THE STAIRWELL AND REBOLTED. PLYWOOD IS NEW AND REINSTALLED, THE TRIM WAS LEFT OFF ALLOWING ME TO SEE THE NEW BOLTS. BOLTS, PLYWOOD POSTS WERE ALL REPLACED LIKE FOR LIKE MATCHING THE EXISTING TAIRWELLS AND WALKWAYS. FOULD 1 BOLT MISSING IN THE RAILING, ASKED MAINTANENCE TO REPLACE OR DRILL AND REPLACE THE BOLT. RAILLINGS FELT STURDY. COMPLIANCE / CLOSE CASE. |
Completed Activity Special Conditions
Case Description - DILAPIDATED STRUCTURE
Case Number - T19DV01395
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
| Date | Name |
| 03/08/2019 | NOTICE OF VIOLATION ISSUED |