Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

02/19/2019

Applicant:

SHIVSHAKTI HOSPITALITY INC

Description:

911 - fire in laundry room

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV01100
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/19/2019 INSP - INITIAL CODE ENFORCMENT BERMUDEZ Approved ON SITE; FIRE ALREADY EXTINGUISHED, ONLY FIRE INVESTIGATOR WALT ON SITE CONDUCTING FIRE INVESTIGATION. TFD CASE NUMBER TFD19-11718. INSPECTOR BERMUDEZ HAD TFD TURN OFF ALL ELECT POWER TO LAUNDRY ROOMS AS IT WAS STILL ON. INSP BERMUDEZ FOUND FIRE, SMOKE AND HEAT DAMAGE THROUGHOUT BOTH LAUNDRY ROOMS LOCATED NEAR POOL AREA. INSPECTOR FOUND MELTED PLUMBING PIPES, HEAT DAMAGE TO ELECTRICAL WIRING AND OUTLETS, SOME DAMAGE TO INTERIOR OF ROOMS, REGISTERS WERE HEAT DAMAMED. POSTED "DO NOT OCCUPY" POSTING ON THE LAUNDRY DOORS. WILL NEED A FULL SET OF PLANS FOR PLUMBING, ELECTRICAL AND MECHANICAL PRIOR TO RECONNECTING ELECTRIC AND GAS SERVICE TO ROOM. ALL WORK MUST BE DONE BY A LICENSED CONTRACTOR. ISSUED 30 DAY NOV TO OBTAIN PROPER PERMITS AND ALSO HAD INDEMNIFICATION FORM SIGNED BY MANAGER JASON DUE TO OWNER JIGER NOT ON SITE. SWG ON SITE CONDUCTING LINE PRESSURE TESTS. THE DETERMINATION OF TESTING IS LINES ARE UNSAFE TO STAY ON DUE TO LEAKS FOUND THROUGHOUT. OWNER TO CONTACT AZ CORP COMM REGARDING REPLACEMENT OF GAS LINES. COMPLEX IS A MASTER METERED SYSTEM, BOILERS ARE AFFECTED, HEATING IS NOT "ELECTRIC". PENDING NOTICE TO VACATE DUE TO LACK OF HOT WATER. MANAGEMENT INFORMED, NOTIFYING OWNER.
10/24/2019 INSP - FOLLOW UP CODE ENFORCE BERMUDEZ Approved CHECKED PERMITS STATUS PER CONTRACTOR. INSPECTOR FOUND PERMITS T19BU00460 FOR THE DEMO OF THE LAUNDRY ROOM AS WELL AS THE ELECTRICAL PANEL RELOCATION. WILL CLOSE CASE AT THIS TIME.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T19DV01100
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 8
Date Name
10/11/2019 CONTACTED BY PHONE
02/20/2019 CONTACTED IN PERSON
03/13/2019 CONTACTED BY EMAIL
02/20/2019 NOTICE AND ORDER ISSUED
02/20/2019 NOTICE OF VIOLATION ISSUED
02/20/2019 STRUCTURE SECURED BY ???
02/20/2019 8-5 CITY COMM EMERGENCY
02/20/2019 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Documents

File Name Document Type  
2019-07-17-13-15-29_AATSC.JPG IMAGES VIEW
2019-07-17-13-15-36_AATSC.JPG IMAGES VIEW
2019-07-17-13-15-42_AATSC.JPG IMAGES VIEW
2019-07-17-13-15-59_AATSC.JPG IMAGES VIEW
2019-07-17-13-16-05_AATSC.JPG IMAGES VIEW
2019-07-17-13-16-47_AATSC.JPG IMAGES VIEW
2019-07-17-13-18-30_AATSC.JPG IMAGES VIEW
2019-07-17-13-18-39_AATSC.JPG IMAGES VIEW
2019-07-17-13-19-28_AATSC.JPG IMAGES VIEW
2019-07-17-13-19-32_AATSC.JPG IMAGES VIEW
2019-07-17-13-19-35_AATSC.JPG IMAGES VIEW
2019-07-17-13-20-07_AATSC.JPG IMAGES VIEW