Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T19DV00375
Case Details
Entered Date:
01/23/2019
Applicant:
LMS PROPERTIES NO 3 LLC 83 1/3% & RENTAL HOLDINGS LLC 16 2/3%
Description:
There are multiple mobile homes that look to be abandoned/boarded up. New (old) travel trailers are being brought on site to be rented out.
Case Violations
Case Number: T19DV00375
Case Status: COMPLIAN
Case Description: RESIDENTIAL ZONING
Total Violations: 4
Violation Date | Code Statue |
---|---|
02/05/2019 | REFERENCE |
02/05/2019 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
02/05/2019 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
02/05/2019 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. |
Outstanding Inspections
Case Number: T19DV00375
Case Status: COMPLIAN
Case Description: RESIDENTIAL ZONING
Total Outstanding Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
NPO(PL)-PLUMBING SYSTEM & FX | None | Not Inspected | ||
NPO(DL)-VACANT & UNSEC.STRUCT | None | Not Inspected | ||
NPO - REFUSE/TRASH/DEBRIS | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T19DV00375
Case Description: RESIDENTIAL ZONING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/05/2019 | INSP - INITIAL CODE ENFORCMENT | MENDOZA | Approved | UNIT 3 LIFE LINE IS SPLICED AT THE PEDESTAL UNIT 5 HAS 30 AMP LIFE LINE AND 40 AMP MAIN BREAKER SPACE 6 HAS AN OPEN SEWER TWO UNITS ON THE PROPERTY ARE VACANT BUT SECURED ACCUMULATION OF TRASH AROUND DUMPSTER AREA |
02/12/2019 | INSP - FOLLOW UP CODE ENFORCE | MENDOZA | Approved | LIFE LINE AT UNIT 3 HAS BEEN REPAIRED MAIN PEDISTAL BREAKER REPLACED WITH 30AMP BREAKER TO MATCH LIFE LINE ALL OPEN SEWERS HAVE BEEN CAPPED TRASH REMOVED |
Completed Activity Special Conditions
Case Description - RESIDENTIAL ZONING
Case Number - T19DV00375
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date | Name |
02/05/2019 | CONTACTED BY PHONE |
02/05/2019 | CONTACTED BY MAILING |
02/05/2019 | CONTACTED BY EMAIL |
02/05/2019 | NOTICE OF VIOLATION ISSUED |
02/12/2019 | VIOLATION CLOSED |