Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

CAR THROUGH RESIDENTIAL BUILDI

Entered Date:

01/14/2019

Applicant:

HOVATER HOVAH C & MIYOKO REVOC LIVING TR

Description:

TPD REQUEST/ CAR INTO BUILDING

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV00226
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Completed Inspections - 3
End Date Description Inspector Results Comments
01/13/2019 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE MET WITH TPD WHO STATED OWNER WAS COMING HOME DRIVING INTO THE DRIVEWAY / CARPORT AREA AND HIT THE GAS RATHER THAN THE BRAKE. MY FINDINGS ARE AS FOLLOWS: >CAR DAMAGED BOTH THE WEST AND EAST BLOCK WALLS OF THE CARPORT STORAGE AREA. THE SOUTH BEARING WALL RECEIVED MINOR CRACKING. THE BLOCK WAS A LIGHT WEIGHT BLOCK AND THERE WAS NO REBAR OR SOLID GROUTING. >THE NORTH WALL WAS A FRAMED/ SHIPLAP SIDING, ENTIRE FRAMED NORTH WALL WAS DAMAGED BY THE CAR. >THERE WAS NO DAMAGE TO THE RAFTERS, RAFTERS SPANNED FROM THE MAIN HOUSE TO THE EXTERIOR BLOCK/ BEAM OF THE STRUCTURE. >THERE WAS A CENTER STEEL I BEAM THAT SUPPORTED THE CENTER OF THE ROOF STRUCTURE. I BEAM REMAINED IN PLACE BUT THE WEST POST WAS KNOCKED OUT AND THE EAST END OF BEAM POCKETED INTO THE WALL THAT WAS DESTROYED. > I BEAM WAS RE SUPPORTED BY C/E AND BOARD UP > ELECTRICAL OUTLETS, SWITCH AND LIGHT FIXTURE WERE TIED IN TO A OUTLET INSIDE THE HOUSE AND RAN THRU THE RAFTERS. C/E WAS UNABLE TO ISOLATE THE ELECTRICAL WITHOUT TURNING OFF ADDITIONAL BREAKERS IN THE SUB PANEL AND OR MAIN PANEL. I DID ROLL THE WIRING AND BOX UP INTO THE CEILING RAFTERS AND HUNG THE ELECTRICAL IN THE RAFTERS. >DAMAGE WAS THE BLOCK WALLS, FRAMED BEARING WALL AND MINOR ELECTRICAL, 3 OPENINGS. >BLOCK AND FRAMED WALLWAS REMOVED FROM ON TOP OF THE CAR AND CAR PULLED OUT OF THE STORAGE AREA AND LEFT IN THE DRIVEWAY. >C/E AND BOARD UP REMOVED THE DEBRIS AND SUPORTED THE BEAM WITH POSTS. OWNER DID NOT WANT THE DAMAGED STORAGE AREA TO BE BOARDED ON EITHER THE EAST OR WEST WALL. >NOV WAS ISSUED FOR PERMITS REQUIRED, TWO COPIES GIVEN TO THE OWNER FOR HIMSELF AND THE INSURANCE COMPANY. > OWNER TRIED CONTACTING INSURANCE AND LEFT A MESSAGE.
01/13/2019 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved
01/14/2019 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved OWNER DID EVENTUALLY MAKE CONTACT WITH THE INSURANCE COMPANY AND WILL MEET WITH WITH THEM ON MONDAY 1/14/2019. C/E EXPLAINED TO THE OWNER WHAT WAS EXPECTED OF THE CONTRACTOR AND MOST IMPORTANTLY THAT A PERMIT BE SECURED. C/E HAS NO FURTHER ISSUES. COMPLIANCE / CLOSE CASE.

Completed Activity Special Conditions

Case Description - CAR THROUGH RESIDENTIAL BUILDI
Case Number - T19DV00226
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
02/05/2019 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS