Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T18DV07926
Case Details
Entered Date:
12/07/2018
Applicant:
FAR HORIZONS MOBILE HOME PARK RESIDENTS COOP ASS
Description:
CAR INTO A MOBILE HOME
Completed Inspections
Case Status: COMPLIAN
Case Number: T18DV07926
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2018 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED SITE, MET WITH TPD OFFICER, FOUND A WHITE VAN PULLING A FLATBED TRAILER LOST CONTROL IN THE MOBILE HOME PARK AND DROVE UP ONTO A ELEVATED PORCH TAKING OUT 3 METAL POSTS OF THE PORCH AND METAL ROOF WAS LEFT LYING ON THE VAN. THERE WAS NO DAMAGE TO THE INTERIOR OF THE MOBILE HOME. I FOUND NO ELECTRICAL OR PLUMBING ISSUES TO THE INTERIOR OR EXTERIOR OF THE STRUCTURE. IT WAS DIFFICULT TO INSPECT THE FOUNDATION TO THE MOBILE HOME BUT SEEMED STABLE, RECCOMEND IT BE INSPECTED BY DSD OR AZ STATE INSPECTOR. >E METAL PORCH POSTS WERE DAMAGED, ALL 5 MAY NEED TO BE REPLACED. >METAL ROOF STRUCTURE TO THE PORCH RECEIVED NO DAMAGE. TRACK THAT SUPPORTS THE POSTS, WAS TWISTED AND WILL NEED TO BE REPLACED. METAL PORCH STRUCTURE IS ATTACHED TO THE MOBILE HOME. >VAN AND TRAILER REMOVED BY GARY'S TOWING. >PORCH SUPPORTED BY 2" X 3" STUDS, 6 STUDS APPROX 6 FT APART. METAL END POSTS REMAINED IN PLACE. >GARY'S REMOVE TRAILER AND VAN AND LEFT THEM OFF 2 HOUSES DOWN. >NOV ISSUED TO OWNER FOR PERMITS REQUIRED AND INFORMED OWNER THAT I WAS UNSURE IF REINSPECTIONS WOULD BE COMPLETED BY COT OR STATE OF AZ. |
| 12/13/2018 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | REVISITED SITE, MET OWNER MRS BROWN, SON THURMON AND FRIEND DENNIS WITKOWSKI WHOM WERE HELPING MRS BROWN RETAIN A CONTRACTOR WHO WAS ABLE TO COMPLETE WORK ON MOBILE HOMES, HELP DTERMINE THE AMOUNT OF DAMAGE TO THE MOBILE HOME AND PROVIDE A PROPOSAL FOR THE WORK NEEDED TO REPAIR THE MOBILE HOME FROM THE DAMAGES RECEIVED BY THE VAN AND TRAILER INTO THE MOBILE HOME ON 12/06/2018. INSPECTOR RICHARD VIDAL AND MYSELF (INSPECTOR GOODMAN) WERE THERE TO INSPECT THE JACKS UNDERNEATH THE TRAILER TO BE SURE THE TRAILER JACKS WERE PROPERLY IN PLACE. INSPECTOR VIDAL REMOVED SKIRTING ON THE WEST SIDE OR THE TRAILER WHERE WE WERE ABLE TO SEE A PART OF THE TRAILER AND JACK SET UP. THERE WERE 4 ROWS OF JACKS IN PLACE, 2 ON THE SOUTH SIDE AND 2 ON THE NORTH SIDE OF THE CENTER PONT OF THE TRAILER, THE JACKS THAT WERE VISABLE WERE ALL PROPERLY IN PLACE AND NOT ALTERED. THERE WAS ONE JACK THAT WAS LEANING BECAUSE OF THE DETERIORATION OF THE 1 INCH THICK PIECE OF PARTICLE BOARD IT WAS SETTING ON. THE EAST SIDE OF THE TRAILER COULD NOT BE SEEN DUE TO A SECTION OF DUCTWORK THAT DID NOT ALLOW UP TO SEE PAST THE MIDDLE OF THE MOBILE HOME. PICTURES WERE TAKEN FOR MRS BROWN ON HER SON'S PHONE. OWNER, SON AND OWNERS FRIEND WERE WORKING ON A CONTRACTOR SO A PERMIT COULD BE OBTAINED. COMPLIANCE /CLOSE CASE. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T18DV07926
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
| Date | Name |
| 12/07/2018 | NOTICE OF VIOLATION ISSUED |