Case: T18DV07860
Case Details
Entered Date:
12/04/2018
Applicant:
DINH THIEN & NGUYEN MONGHUYEN CP/RS
Description:
ROACHES, PLUMBING AND ELECTRICAL ISSUES 02/13/2019 GAS IS OFF DUE TO A LEAK NO HOT WATER NO HEAT
Case Violations
Case Number: T18DV07860
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
Violation Date | Code Statue |
---|---|
12/14/2018 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
12/14/2018 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (3) Every habitable room must have at least two electrical receptacle outlets, or one outlet and one electric light fixture. Every bathroom, water closet compartment, and laundry room must have at least one electric light fixture. |
12/14/2018 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
12/17/2018 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
12/17/2018 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
12/17/2018 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
12/17/2018 | T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. |
Completed Inspections
Case Status: COMPLIAN
Case Number: T18DV07860
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/11/2018 | INSP - INITIAL CODE ENFORCMENT | MORALES | Approved | ON SITE WITH TENANT. FRONT WINDOW AND BATHROOM WINDOW NOT WORKING PROPERLY. COVER PLATES MISSING ON ELECTRICAL OUTLETS AND SWITCHES. EXPOSE WIRES IN BEDROOM. HOT WATER HEATER AND AIR FILTER DOORS ARE MISSING VENT COVERS. FRONT AND REAR DOOR MISSING WEATHER STRIPPING. BATHROOM SINK IS LEAKING. NO SMOKE DETECTORS IN UNIT. |
02/13/2019 | INSP - FOLLOW UP CODE ENFORCE | MORALES | Approved | CASE WILL BE CLOSE DUE TOT TENANT NOT LIVING AT UNIT. INFORM OWNER UNIT MUST BE IN CODE BEFORE NEW TENANT CAN OCCUPY UNIT. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T18DV07860
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date | Name |
12/24/2018 | CONTACTED BY PHONE |
12/14/2018 | CONTACTED BY MAILING |
12/14/2018 | NOTICE OF VIOLATION ISSUED |
02/13/2019 | VIOLATION CLOSED |