Description:

cieling has hole . floor is warped ***11/09/18 -update.. ceiling has now collapsed kitchen/living room - 2 years. When it rains, everything gets wet. Bathroom floor warped, tiles broken. Kitchen sink -water damage underneath. Swamp cooler may soon fall through ceiling due to all the water damage.

Case Violations

Case Number: T18DV06924
Case Status: NOVERIFY
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
Violation Date Code Statue
11/15/2018 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
11/15/2018 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability.
11/15/2018 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
11/15/2018 T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition.
11/15/2018 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
11/15/2018 T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly.
11/15/2018 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.

Completed Inspections

Case Status: NOVERIFY
Case Number: T18DV06924
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/14/2018 INSP - INITIAL CODE ENFORCMENT HOLLANDER Approved Viewed with tenant and found open drywall ceilings with evidance of roof leakage. Floor tiles loose or missing. Heater reported inoperable. SD missing. Bath fan missing and vent covered in dust. Kitchen exhaust fan coveered in grease. Windows not operable.
12/18/2018 INSP - FOLLOW UP CODE ENFORCE HOLLANDER Approved In progress in kitchen ceiling. Need to do bedroom ceiling and other items.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T18DV06924
Case Status: NOVERIFY
Total Completed Case Activity Conditions: 4
Date Name
04/13/2020 CONTACTED BY PHONE
11/15/2018 CONTACTED BY MAILING
11/15/2018 NOTICE OF VIOLATION ISSUED
04/13/2020 VIOLATION CLOSED