Case: T18DV06328
Case Details
Entered Date:
10/03/2018
Applicant:
KAREN L BRUNING 1/2 & RANDY W SIMONS 1/2
Description:
TPD CALLED -HOME W/OUT WATER - CHILD LIVING IN HOME WATER OFF SINCE 9/4/18 5/16/19-caller states house is condemned (?) and she believes there are squatters in back shed. Board up window is down./Pat
Case Violations
Case Number: T18DV06328
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 10/03/2018 | REFERENCE |
| 10/03/2018 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 10/03/2018 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 10/03/2018 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 10/03/2018 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
Outstanding Inspections
Case Number: T18DV06328
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 6
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected | ||
| NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
| NPO(PL)-PLUMBING SYSTEM & FX | None | Not Inspected | ||
| NPO(PL)-WATER HEATERS | None | Not Inspected | ||
| NPO - WORK WITHOUT PERMIT | None | Not Inspected | ||
| NPO - INT. BUILDING MAINTENANC | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T18DV06328
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/03/2018 | INSP - INITIAL CODE ENFORCMENT | MENDOZA | Approved | OCCUPANT ALLOWED ENTRY TO CODE AND TPD FOR INTERIOR INSPECTION AND TPD WELFARE CHECK. UNIT LACKS WATER SERVICE. OFF SINCE 9/4/18. TPD ON SITE. HAZARDOUS ELECTRICAL THROUGOUT. REAR SHED HAS AN ELECTRICAL CORD CONNECTED TO LIGHTS AND WALL A/C UNIT AND APPEARS TO BE OCCUPIED AS A DWELLING ELECTRICAL RUNS TO THE REAR OF THE STRUCTURE, OPEN PANEL BOX BEING USED AS A J BOX WITH SPLICES ADDED ELECTRICAL CONNECTION AT THE BOTTOM OF THE MAIN PANEL BOX. NOT SECURED AND NOT APPROVED FOR OUTDOOR USE ADDED ELECTRICAL IN THE KITCHEN AREA WITH OUTLET BOX MOUNTED IN A SHELF AREA GAS WATER HEATER REMOVED AND REPLACED WITH AN ELECTRICAL WATER HEATER AT THE EXTERIOR REAR OF THE UNIT DRYER BEING RUN WITH A PROPANE TANK. I CLOSED THE VALVE AND REMOVED THE TANK. FRONT DOOR JAM IS SEVERLY DAMAGED REAR PORCH ADDED WITHOUT PERMIT UNIT CONDEMNED FOR LACK OF WATER SERVICE AND UNSAFE ELECTRICAL TEP CALLED TO REMOVE THE ELECTRICAL METER AND REQUESTED CLEARANCE FOR RE-CONNECT ARCADIAN CALLED FOR BOARD UP OF THE UNIT WINDOW, DOORS AND REAR SHED |
| 11/29/2018 | INSP - FOLLOW UP CODE ENFORCE | MENDOZA | Approved | PROPERTY SECURE. ALL TRASH HAS BEEN REMOVED |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T18DV06328
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 8
| Date | Name |
| 10/03/2018 | CONTACTED BY PHONE |
| 10/12/2018 | CONTACTED IN PERSON |
| 10/03/2018 | CONTACTED BY MAILING |
| 10/12/2018 | NOTICE AND ORDER ISSUED |
| 10/03/2018 | NOTICE OF VIOLATION ISSUED |
| 11/29/2018 | VIOLATION CLOSED |
| 11/30/2018 | SEC LETTER OF BILLING FOR $??? SENT TO OWNERS |
| 10/03/2018 | STRUCTURE SECURED BY ??? |