Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES
Address:

Entered Date:

09/27/2018

Applicant:

5TH & CAMELBACK TUCSON LLC & 22ND & KOLB LLC ATTN: SCOTIA GROUP MGMT LLC

Description:

cieling collappsed

Case Violations

Case Number: T18DV06160
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 3
Violation Date Code Statue
10/02/2018 T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration.
10/02/2018 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element.
10/02/2018 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.

Completed Inspections

Case Status: COMPLIAN
Case Number: T18DV06160
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/02/2018 INSP - INITIAL CODE ENFORCMENT LOPEZ Approved After inspection to unit 128 did see some minor repairs to ceiling where condensation was leaking unfortunately ceiling was repaired before leak was established will need to service AC condensation first , 0 days, then within five days replace ceiling after moister has dried. Also in notice will be exterior front and rear doors need weatherstripping, needs to be repair exterior hole in backyard and under kitchen sink properly, and exterior wood fence needs to be painted for weather protection.
11/01/2018 INSP - FOLLOW UP CODE ENFORCE LOPEZ Approved NOW THAT MAINTENANCE PERSON AND MANAGER HAVE AXCESS TO UNIT, DID FOLLOW UP INSPECTION AND FOUND THAT ALL VIOLATIONS HAVE BEEN ABATED, I APPOVED FOR FENCE NOT BEING PAINTED, DUE TO COMPLEX IS REPLACEING ALL FENCES, WORK HAS STARED AT THE OTHER END OF COMPLEX, WILL BE CLOSING THIS CASE.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T18DV06160
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
10/15/2018 CONTACTED IN PERSON
10/02/2018 NOTICE OF VIOLATION ISSUED