Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T18DV05188
Case Details
Entered Date:
08/28/2018
Applicant:
AZ COMMONS LLC ATTN KEVIN EASTERLY
Description:
Excessive Lighting - Lighting from this apartment complex behind 3647 E. 2nd St. is extremely bright and comes directly into our windows starting at 6pm - equivalent to mid-morning light in the middle of the night.
Completed Inspections
Case Status: COMPLIAN
Case Number: T18DV05188
Case Description: LIGHTING VIOLATION
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/06/2018 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | OUT DOOR LIGHTING VIOLATION, THE APARTMENT COMPLEX HAS TEN OUTDOOR LIGHT FIXTURES THAT ARE NOT FULL CUT OFF AND ARE CAUSING "LIGHT TRESPASSING" ONTO THE RESIDENTIAL NEIGHBORHOOD. THESE FIXTURES WERE INSTALLED WITHOUT A PERMIT. |
| 11/07/2018 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ALL VIOLATIONS ABATED ,, CLOSE CASE |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 09/11/2018 | 2012 TUCSON/ PIMA COUNTY OUTDOOR LIGHTING CODE SECTION 104 PERMITS AND PLAN SUBMISSION REQUIREMENTS 104.1 PERMITS REQUIRED. ANY OWNER OR AUTHORIZED AGENT WHO INTENDS TO INSTALL, CONSTRUCT, ENLARGE, ALTER, REPAIR, MOVE, OR CHANGE ANY OUTDOOR LIGHTING WITHIN PIMA COUNTY JURISDICTION, THE INSTALLATION OF WHICH IS REGULATED BY THIS CODE, SHALL FIRST MAKE APPLICATION TO THE BUILDING OFFICIAL FOR PIMA COUNTY AND OBTAIN THE REQUIRED PERMIT 2012 TUCSON/ PIMA COUNTY OUTDOOR LIGHTING CODE 401.3 SHIELDING REQUIREMENTS. ALL LIGHT FIXTURES THAT ARE REQUIRED TO BE SHIELDED SHALL BE INSTALLED IN SUCH A MANNER THAT THE SHIELDING IS EFFECTIVE AND PERMANENT. 401.3.1 LIGHT TRESPASS. LIGHT FIXTURES ON THE RESIDENTIAL SIDE OF COMMERCIAL PROPERTY ADJACENT TO RESIDENTIAL PROPERTY SHALL BE FULL CUTOFF AND SHALL BE INSTALLED NOT HIGHER THAN 10 FEET ABOVE GRADE AT THE PROPERTY LINE AND NO HIGHER THAN A LINE RISING 20 DEGREES ABOVE THE 10 FEET UNTIL 100 FEET FROM THE PROPERTY LINE, MEASURED PERPENDICULAR TO THE LOT LINE 401.3.3 FIXTURES WITHIN 25 FEET OF RESIDENTIAL LOT LINES. RESIDENTIAL AND COMMERCIAL LUMINAIRES SHALL BE FULL CUTOFF WITHIN 25 FEET OF ADJACENT RESIDENTIAL PROPERTY LINES, MEASURED PERPENDICULAR TO THE LOT LINE | Not Approved |
Completed Activity Special Conditions
Case Description - LIGHTING VIOLATION
Case Number - T18DV05188
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 09/11/2018 | CONTACTED BY PHONE |
| 09/11/2018 | CONTACTED BY EMAIL |
| 09/11/2018 | NOTICE OF VIOLATION ISSUED |