Case: T18DV04885
Case Details
Entered Date:
08/17/2018
Applicant:
MC GUFFIN JIM & MC GUFFIN JACOB JT/RS
Description:
COMMUNICATION CALLED THAT T.O.D. ON SITE WITH HAZARDOUR ELECTRICAL, E182281272, 1808160212
Completed Inspections
Case Status: COMPLIAN
Case Number: T18DV04885
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/17/2018 | INSP - INITIAL CODE ENFORCMENT | VIDAL | Approved | Communication called that T.P.D. on site with hazardous electric. Arrived and the units still on site and talking to the owner. They have electric breakers that were removed and not allowing power to certain areas due to a dispute between the owners and the people staying in a room. Did go over that the landlord tenant act needs to be enforced at this time but not able to remove power to tenants at any time to have them removed. Did advised the owner that if the breakers were re-installed at this time that the power will remain on. If the breakers are not installed the power will be removed due to the amount of wires that are not connected and are not in a save condition with out the breakers. The house has added rooms and the electrical is being added to areas and not being done corrected. Has open splices and not in junction boxes, new electrical outlets, switches and light boxes added through out the house, walls are being removed such as closets to connect to other areas to make the room bigger, porches enclosed to rooms, has double lugging at the main disconnect on the exterior of the house. The owner did sign the N.O.V. for work with out permits and went over all the issues. The owner stated that he bought the property from the bank as is and went over that he is still responsible for the issues that need to be corrected. Did go over the AC package unit on the roof that will also need to be permitted due to the furnace has been removed from the room where the water heater was installed. Has new PEX and more on the cold side. Did let the owner know that will be checking in a month to check on the progress of the permit or the work being done. RV. |
| 02/08/2019 | INSP - FOLLOW UP CODE ENFORCE | VIDAL | Approved | This case will be going to the area inspector for other issues on the property. Does have a case under inspector Vindiola at this time. At this time the case will be closed. Violation Abated, Close Case. RV. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T18DV04885
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 08/17/2018 | NOTICE OF VIOLATION ISSUED |
| 02/09/2019 | VIOLATION CLOSED |
| 08/17/2018 | STRUCTURE SECURED BY ??? |