Description:
the foundation of the property is cracking . FRONT DOOR WILL NOT SHUT UNSECURED
Case Violations
Case Number: T18DV03470
Case Status: COMPLIAN
Case Description: RESIDENTIAL ZONING
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 06/19/2018 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
Outstanding Inspections
Case Number: T18DV03470
Case Status: COMPLIAN
Case Description: RESIDENTIAL ZONING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| NPO(DL)-DILAPIDATED STRUCTURE | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T18DV03470
Case Description: RESIDENTIAL ZONING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/15/2018 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | SITE INSPECTION, THERE ARE STRUCTURAL CRACKS TO THE DWELLING. THE DWELLING IS BLOCK CONSTRUCTION WITH HORIZONTAL SEPARATION IN THE MORTAR JOINT MID WAY OF THE DWELLING, AREA OF DAMAGE IS ABOUT 5 FEET IN BOTH DIRECTIONS FROM THE SOUTH EAST CORNER OF THE DWELLING. THERE ARE MULTIPLE STAIR WAY TYPE CRACKS IN THE SAME AREA BOTH SIDES FROM THE FOUNDATION TO MID WAY OF THE DWELLING, ALL THE STRUCTURAL CRACK ARE VISIBLE FROM THE INTERIOR OF THE BEDROOM. IT APPEARS THE DAMAGE AREA'S FOUNDATION HAS SUNK INTO THE EARTH DUE TO A WATER LEAK UNDER THE FOUNDATION. MADE CONTACT WITH OWNER ON SITE: THE DWELLING WAS EVALUATED BY LICENSE CONTRACTOR AND MONDAY THE ENGINEER AND AMERICAN LEAK DETECTION ARE SCHEDULE TO CONDUCT INSPECTION. OCCUPANCY CONTINUES. |
| 08/16/2018 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | (T18DV03470) FOUNDATION REPAIR PERMIT IS FINAL .. CLOSE CASE |
Completed Activity Special Conditions
Case Description - RESIDENTIAL ZONING
Case Number - T18DV03470
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 06/14/2018 | CONTACTED BY PHONE |
| 06/19/2018 | CONTACTED IN PERSON |
| 06/19/2018 | CONTACTED BY MAILING |
| 06/19/2018 | NOTICE OF VIOLATION ISSUED |
| 06/14/2018 | RESEARCH |