Case Details
Entered Date:
06/12/2018
Applicant:
RAYMUNDO & ALMA A OLVERA & RUBEN HUERTA
Description:
UNIT 4 - PLUMBING PROBLEMS, EXTERIOR DOORS, RODENTS
Case Violations
Case Number: T18DV03387
Case Status: REFERRED
Case Description: MULTIPLE TYPES
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 06/25/2018 | T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced. |
| 06/25/2018 | T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons. |
| 06/25/2018 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 06/26/2018 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
| 06/26/2018 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
Completed Inspections
Case Status: REFERRED
Case Number: T18DV03387
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2018 | INSP - INITIAL CODE ENFORCMENT | MMENDOZA | Approved | ON SITE INSPECTION WITH TENANT , FOUND EVIDENCE OF RODENT INFESTATION THROUGHOUT APARTMENT, FRONT ENTRY DOOR NOT SEALED PROPERLY, COOLER BLOWING HOT AIR, WATER PIPES TO WATER HEATER NOT CONNECTED, WATER HEATER FLUE NOT INSTALLED PROPERLY, |
| 06/25/2018 | INSP - FOLLOW UP CODE ENFORCE | MMENDOZA | Approved | SPOKE WITH OWNER BU PHONE , ADVISED HIM OF THE PENDING NOTICE OF VIOLATION |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T18DV03387
Case Status: REFERRED
Total Completed Case Activity Conditions: 3
| Date | Name |
| 06/26/2018 | CONTACTED BY PHONE |
| 06/26/2018 | NOTICE OF VIOLATION ISSUED |
| 04/07/2020 | VIOLATION CLOSED |