Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

06/07/2018

Applicant:

BRIAN & MARGEAUX BOWERS CP/RS

Description:

Unit B: roach and mice infestation; gaps around front door; evaporative cooler blows weakly at high, nothing at low, missing drawers and broken cabinent doors in kitchen.

Case Violations

Case Number: T18DV03275
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 9
Violation Date Code Statue
06/21/2018 REFERENCE
06/21/2018 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
06/21/2018 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
06/21/2018 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
06/21/2018 T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration.
06/21/2018 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
06/21/2018 T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons.
06/21/2018 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.
06/21/2018 T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly.

Outstanding Inspections

Case Number: T18DV03275
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
NPO(HC)-COOLING None Not Inspected
NPO - INSECTS/PESTS None Not Inspected
NPO - INT. BUILDING MAINTENANC None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T18DV03275
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/21/2018 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved FRONT DOOR FRAME IS DAMAGED FRONT DOOR DOES NOT SEAL PROPERLY CABINETS IN THE KITCHEN AND BATHROOM OF MISSING DOORS AND DRAWERS EVIDENCE OF A ROACH INFESTATION. LIVE ROACHES SEEN THROUGHOUT THE UNIT COOLER NOT WORKING PROPERLY. ONLY ONE SPEED WITH NO VOLUME COMING FROM THE VENTS MISSING OUTLET COVERS THROUGHOUT THE UNIT SOUTH BEDROOM DOOR JAM IS BROKEN AND DETERIORATED EXTRA BEDROOM DOOR HAS A HOLE AND IMPROPER DOOR KNOB EVIDENCE OF A LEAK IN EXTRA BEDROOM CEILING KITCHEN WINDOW DOES NOT OPERATED PROPERLY BATHROOM IS MISSING AN OPERATIONAL FAN, DOOR JAM IS BROKEN AND DETERIORATED WATER HEATERS ENCLOSURE IS MISSING A DOOR AND IS DETERIORATED. TRPV DRAIN PIPE ARE NOT AT THE PROPER HEIGHT. SMALL TREE BLOCKING PROPER ACCESS TO THE WATER HEATERS
09/26/2018 INSP - FOLLOW UP CODE ENFORCE MENDOZA Approved MET WITH OWNER, WALKED UNIT AND VERIFIED ALL VIOLATIONS HAVE BEEN ADDRESSED

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T18DV03275
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
08/02/2018 CONTACTED BY PHONE
06/21/2018 CONTACTED BY MAILING
06/21/2018 NOTICE OF VIOLATION ISSUED
09/26/2018 VIOLATION CLOSED
09/05/2018 COURT HEARING INFO