Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T18DV02799
Case Details
Entered Date:
05/16/2018
Applicant:
LMLN PROPERTIES LLC
Description:
CAR INTO BUILDING
Outstanding Inspections
Case Number: T18DV02799
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T18DV02799
Case Description: EMERGENCY
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/15/2018 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | MET WITH TPD OFFICERS WHO INFORMED ME OF THE CAR INTO THE BUILDING BEING FORCED INTO THE BUILDING BY AN ACCIDENT THAT OCCURRED AT THE CORNER OF SPEEDWAY AND EUCLID. THE PROPERT AFFECTED WAS 812 E SPEEDWAY AT THE S/E CORNER. TFD WAN'T TO KNOW IF THE STRUCTURE WAS LIVABLE. MY FINDINGS ARE AS FOLLOWS: >CARS WERE REMOVED BY GARY'S TOWING IN THE STREET, AND ROD ROBERTSON EMOVED THE CAR NEAR THE PORCH. >ARCADIAN HELPED WITH THE SHORING. >ENTERED STRUCTURE WITH OCCUPANT ANDRE PERRAULT, HE WAS SITTING ON THE COUCH LOCATED AT THE EXTERIOR FRONT PORCH AREA ON THE EAST SIDE OF THE STRUCTURE. I FOUND EXISTING CRACKING IN THE WALLS AND CEILING THAT DID APPEAR TO HAVE BEEN PATCHED, VERIFIED BY ANDRE AND WOOD SPINDLE WALL NEAR THE ENTRY DOOR THAT IS LEANING BUT ANDRE STATED THE WALL HAS BEEN THAT WAY SINCE HE MOVED IN. >ELECTRICAL ALL SEEMED TO BE WORKING OK WITH NO PROBLEMS. TFD WAS ON SITE AND DID NOT SHUT THE POWER OFF. C/E HAD NO REASON TO CUT POWER. >CAR HIT THE PILLAR AT THE N/W CORNER OF THE PORCH. PILLAR BEARING THE RAFTERS AND ROOF SHEATHING AND COVERING, WAS COMPLETELY DAMAGED AND THE ROOF PARTIALLY COLLAPSED. >THE CENTER BEAM BEARING ON A BEAM RUNNING EAST AND WEST FROM COLLUM TO COLLUM WAS ALSO REMOVED FROM THE WEST PILLAR ALLOWING THE CENTER BEARING BEAM TO SAG OR PARTIALLY COLLAPSE BUT NOT NEARLY AS BAD AS THE WEST BEARING BEAM. > THE EAST SIDE OF THE PORCH REMAINED INTACT THE WEST SIDE OF THE PORCH WAS PARTIALLY COLLAPSED. THERE WAS NO STRUCTURAL DAMAGE TO THE MAIN STRUCTURE. >THE WEST AND CENTER BEAM WERE TEMPORARILY POSTED AND SUPPORT SO THERE WOULD BE NO FURTHER COLLAPSE AND THE FRONT PORCH TAPED OFF WITH CAUTION TAPE TO PRVENT USAGE OF THE PORCH. OCCUPANT WAS INFORMED THAT THE PORCH WAS NOT TO BE USED. >OWNER BILL HUBBARD WAS ON SITE BUT BECAUSE OF THE TIME OF THE ACCIDENT, LEFT EARLY WITHOUT A NOV BEING ISSUED. I EXPLAINED I WOULD ISSUE AND SEND THE NOV VIA MAIL. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T18DV02799
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date | Name |
05/17/2018 | NOTICE OF VIOLATION ISSUED |