Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

03/26/2018

Applicant:

MALAK RANDALL W LIVING TR

Description:

HOUSE FIRE

Completed Inspections

Case Status: COMPLIAN
Case Number: T18DV01627
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
03/26/2018 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, MET WITH TFD INVESTIGATORS, FOUND GARAGE ON THE EAST SIDE OF THE STRUCTURE HAD BURNED. FIRE WAS LIMITED TO THE GARAGE AREA AND MINOR DAMAGE TO THE HALLWAY WHERE THE GARAGE ENTERED THE HOUSE. OWNER IS A AUTO MECHANIC, USED TO WORK FOR ORIELLY'S AS A MECHANIC SUPERVISOR. HE WAS WORKING ON A VW WAGON, CAR UP ON JACKS AND SUPPOSEDLY WHEN HE WENT TO START THE ENGINE THERE WAS A SPARK AND LOUD EXPLOSION THAT BLEW THE GARAGE DOORS OFF, (3) CAR GARAGE, AND BURNED ALL DRYWALL THRU OUT THE GARAGE AREA. OWNER WAS TAKEN TO THE HOSPITAL, SO NOT PRESENT AT THE TIME OF MY INSPECTION, NEIGHBOR RITCHIE MARTINEZ WAS ON SITE TO REPRESENT THE OWNER RANDY MALAK. MY FINDINGS ARE AS FOLLOWS: >FOUND SERVICE TO THE ELECTRICAL PANEL HAD BEEN CUT AND METER LOCKED OUT. NEW 200 AMP SERVICE WAS WELL MARKED AND NEWLY INSTALLED OR 200 AMP UPGRADE IN 2011 UNDER PERMIT. RECONNECT REQUIRED >S/W GAS CUT THE GAS TO THE METER AND PINNED THE METER. GAS RECONNECT REQUIRED. >DRYWALL THRU OUT THE GARAGE WAS FIRE DAMAGED. ROOF TRUSSES OK >44 LINEAL FEET OF THE FRONT EVES, RAFTER TAILS AND FACIA FIRE DAMAGED. > HOUSE WAS WOOD FRAME AND T-111 SIDING, 3-4 SHEETS OF T-11 SIDING FIRE DAMAGED. >16 FT AND 8 FT GARAGE DOORS FIRE DAMAGED >ELECTRICAL WIRING, SWITCHES AND OUTLETS, LIGHTING FIXTURES AND APPLIANCES FIRE DAMAGED. ELECTRICAL WIRING LEFT EXPOSED. >FIRE DID NOT MOVE INTO THE ATTIC SPACE. >FIRE DID MOVE INTO THE ENTRY HALL FROM THE GARAGE TO THE HOUSE. MINOR FRAMING DAMAGE IN THE WALLDUE TO FIRE. ELECTRICAL AND GAS WERE LEFT OFF, ARCADIAN WAS CALLED TO BOARD REAR GARAGE DOOR, DOOR FROM GARAGE TO HOUSE AND BOTH GARAGE DOOR OPEINGS, 28 LINEAL FT. NOV WAS ISSUED AND SIGNED FOR BY THE OWNERS REPRESENTATIVE RITCHIE MARTINEZ. NEIGHBOR. GARAGE STRUCTURE WAS POSTED "UNFIT TO OCCUPY" HOUSE DOORS LOCKED UP BY RITCHIE MARTINEZ.
03/28/2018 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved CONTACTED BY OWNERS GIRLFRIEND KAREN ASKING PROCEDURES TO MAKE REPAIRS TO THE GARAGE. WENT OVER INSURANCE, CONTRACTOR AND PERMITTING ISSUES. INFORMED THEM OF ELECTRICAL AND GAS RECONNECTS. AND WHEN AND WHEN NOT THEY SHOULD BE IN SIDE THE HOUSE. INSURANCE COMPANY ALREADY HAS BEEN CONTACTED. ALL ISSUES HAVE BEEN ADDRESS TO THIS POINT., NO FURTHER VIOLATIONS. COMPLIANCE / CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T18DV01627
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
03/29/2018 NOTICE OF VIOLATION ISSUED