Case: T18DV00651
Case Details
Entered Date:
02/07/2018
Applicant:
RUDY P & MARIE ANGELIC ORTIZ JT/RS
Description:
COMMERCIAL FIRE
Outstanding Inspections
Case Number: T18DV00651
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T18DV00651
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/07/2018 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED SITE, UPON ARRIVAL I FOUND SEMI TRAILERS ONLY ON PART OF THE PROPERTY, SEMI RIGGS ONLY ON ANOTHR PART OF THE PROPERTY AND THE COMPLETED SEMI AND TRAILER ON A THIRD PORTION. BEHIND THE OFFICE AND PERSONAL STORAGE AREA AT THE N/E CORNER OF THE PROPERTY WAS A VERY LARGE AWNING WERE REPAIRS WERE DONE TO THE 18 WHEELERS. THE AWNING PORTION WAS APPROX 48 FT X 68 FT AND 20-24 FT IN HEIGHT, BUILT WITH 4-5 INCH STEEL POSTS, HEAVY 3" X 12" METAL BEARING BEAMS AND 2" X 6 " METAL RAFTERS AND A CORRIGATED METAL ROOF. BELOW THE AWNING WAS A TRAILER BEING REPAIRED AND TWO RIGGS. FOUND SEVERAL REFRIGERATION UNITS AND COMPLETE ENGINES AS WELL. OWNERS TOOLS, COMPRESSORS, GENERATORS, FORK LIFTS, MEHANICS TOOLS AND BOTH ELECTRIC AND AIR TOOLS. >MET WITH TEP WHEN I FIRST ARRIVED, TEP STATED THAT TFD WAS CONCERNED ABOUT SOME SUSPICOUS WIRING BUT FOUND IT MAY BE CABLE BUT NOTHING THEY, TEP WERE CONCERNED ABOUT. ELECTRICAL SERVICE PANEL WAS ON THE MAIN STRUCTURE APPROX 16 TO 20 FT AWAY. TEP TURNED POWER OFF AT THE BREAKERS ONLY SO THAT POWER COULD BE ISOLATED. POWER WAS RESTORED TO THE MAIN STRUCTURE, BREAKERS TO ALL HEAVY EQUIPMENT WAS LEFT OFF AT THIS TIME. > S/W GAS WAS NOT INVOLVED AT THIS PROPERTY. >TFD HAD NOT YET DETERMINED THE CAUSE OF THE FIRE, THERE WERE CAMERAS ON SITE THAT SHOWED WHERE THE FIRE HAD STARTED. > A WORKER WORKING ON THE TOP OF THE TRAILER RIVETING THE METAL TOGETHER AND THEN CUTTING RIVETS OFF WITH A GRINDER AND HOT METAL SPARKS COMING OFF THE GRINDER MAY HAVE BEEN THE CAUSE OR START OF THE FIRE, BUT THE TRAILER WAS SURROUNDED BY FORK LIFTS, 2 RIGGS AND A SHED WITH PAINTS AND OTHER CHEMICALS THAT MAY HAVE AIDED IN THE EXPLOSION. TIRES AS WELL. >STEEL POSTS STAYED INTACT, RAFTERS WERE BENT AND TWISTED. CORRAGATED METAL FIRE DAMAGED. > NOV FOR PERMITS REQUIRED WAS ISSUED TO THE OWNER AND SIGNED FOR BY THE OWNER RUDY ORTIZ. RUDY STATED HE DID HAVE INSURANCE, THEY HAVE ALREADY MADE CONTACT WITH THE NSURANCE COMPANY. I EXPLAINED THE NOV PROCESS AFTER INSURANCE COMPLETED THEIR INSPECTION. >CLOSE CASE PER ADMINISTRATOR. |
Completed Activity Special Conditions
Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T18DV00651
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
| Date | Name |
| 02/08/2018 | NOTICE OF VIOLATION ISSUED |