Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

10/18/2017

Applicant:

SABRINA ELIZABETH PINA-MINARD

Description:

AIR CONDITIONER WILL NOT TURN OFF, DIRECTLY WIRED, THERMOSTAT DOESN'T WORK. LEAK UNDER SINK, MANAGER PUT SINK UNDER BUCKET AND HAS NOT COME TO FIX THE SINK LEAK. POOL IN COMPLEX IS BEING USED FOR STORAGE.WEEDS AND GRASS OVER 6 INCHES ALL OVER PROPERTY. FAUCET KNOBS ON KITCHEN SINK AND BATHROOM HAS NO KNOBS USES PLIERS TO OPEN FAUCETT. FRONT DOOR LOCK DOES NOT LOCK AND DOESN'T LOCK.4 ABANDONED CARS IN PARKING LOT.

Case Violations

Case Number: T17DV05441
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
Violation Date Code Statue
10/25/2017 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
10/25/2017 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
10/25/2017 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
10/25/2017 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element.

Outstanding Inspections

Case Number: T17DV05441
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
NPO(PL)-PLUMBING SYSTEM & FX None Not Inspected
NPO(HC)-COOLING None Not Inspected
NPO(DL)-DILAPIDATED STRUCTURE None Not Inspected
NPO - REFUSE/TRASH/DEBRIS None Not Inspected
NPO - EXT. BUILDING MAINTENANC None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV05441
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/19/2017 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved SPOKE WITH TENANT AND OWNER. OWNER STATED ALL DAMAGE IS BEING CAUSED DUE TO EVICTION AND CONTINOUS POLICE ACTION AT THE UNIT. EVICTION COURT TO TAKE PLACE 10/20/17. TENANTS SHOULD VACATE THE UNIT WITHIN 7 DAYS.
10/25/2017 INSP - FOLLOW UP CODE ENFORCE MENDOZA Approved A/C UNIT FAN DOES NOT SHUT OFF EVEN THOUGH THERMOSTAT IS SET TO OFF. KTICHEN SINK FAUCET IS NOT SECURE AND IS MISSING THE HANDLES TO OPERATE THE FAUCET. DRAIN PIPE FOR THE KITCHES FAUCET IS LEAKING AND WATER BEING CAPTURED IN BUCKET. KITCHEN CABINETS ARE MISSING ALL SHELVING IN ALL CABINETS. ONE CABINET IS MISSING THE DOOR. BATHTUB FAUCET IS MISSING THE HANDLE TO OPERATE THE FAUCET. EXTERIOR CLOSET COVERING IS DETERIORATED AND IS MISSING PORTIONS OF WOOD AT THE BOTTOM HALF OF THE CLOSET. ENTIRE REAR AREA OF BUILDING IS FULL OF ANIMAL WASTE AND MISC. TRASH, THOUGH AREA BEHIND UNIT IS BEING MAINTAINED.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T17DV05441
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
10/24/2017 CONTACTED BY PHONE
10/25/2017 CONTACTED BY MAILING
10/25/2017 NOTICE OF VIOLATION ISSUED
01/10/2018 VIOLATION CLOSED
10/26/2017 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition.